I m p o r t a n t s a f e g u a rd s
• Use this appliance only as described in this instruction manual.
As with any electrical appliance, the instructions aim to cover as many
eventualities as possible. Caution and common sense should be used
when operating and installing this air conditioner.
• This appliance has been manufactured to cool and dehumidify
domestic environments and should not be used for other purposes.
• It is dangerous to alter or modify the unit's characteristics in any way.
• The appliance must be installed in line with the relevant national legi-
slation.
• Should repairs be necessary, contact the nearest authorized De'Lon-
ghi Repair Service Center. Unauthorized Delonghi servicing can be
dangerous.
• This appliance is to be used by adults only; keep away from children.
• In the case that the power cord becomes damaged, this must be substi-
tuted only by specialized personnel authorized by the manufacturer.
• Always ensure the appliance is grounded. If you have any doubts
check with a qualified electrician.
• Avoid using extension cords with the unit.
• Before cleaning or maintenance operations, always unplug the unit
from the outlet.
• Do not pull on or place strain on the power cord when moving the
appliance.
• The appliance should not be installed where the atmosphere may
contain combustible gases, oil or sulphur, or near heat sources.
• Do not rest hot or heavy objects on the appliance.
• Remember to perform the descaling procedure at the end of each
season (see page 13). In areas where the water is particularly hard
(rich in minerals), the use of a commercial descaling product added
to the water is recommended. This can be requested to De'Longhi
America, Inc.
• Clean the filters at least once a week.
• Avoid using heaters near the unit.
The unit, should be transported in a vertical position. If this is not
possible secure the unit at an angle, do not lie it horizontally.
• Before transporting the unit, drain the condensation collecting-tray
and tank. After transportation, wait at least 1 hour before switching on
the unit.
• The packaging materials can be recycled. You are therefore recom-
mended to place them in the special containers for differentiated
waste collection.

SAVE THESE INSTRUCTIONS

4

Advertisement

Table of Contents
loading

Summary of Contents for DeLonghi PAC 700T

  • Page 1: Save These Instructions

    • The appliance must be installed in line with the relevant national legi- slation. • Should repairs be necessary, contact the nearest authorized De’Lon- ghi Repair Service Center. Unauthorized Delonghi servicing can be dangerous. • This appliance is to be used by adults only; keep away from children.
  • Page 2 75°F (24 °C) and 50% relative humidity. An air conditioner removes moisture and heat from the room where it is located. One advantage of portable air conditioning units over window models is that they can easily be moved from one room to another in the home or even transferred between different buildings.
  • Page 3 Insert the nozzle of the exhau- st hose into the slot, then connect the hose to the air conditioner (Fig. D). With the wing nut it’s possible to use the window bracket also for sliding windows. Position the hole of the bracket to allow a correct instal- lation of the exhaust hose.
  • Page 4 S e t t i n g u p If you have a sliding door, use the additional set provided in order to extend the accessory to the desired length; joining the two parts (fig. E), adjust the total length according to your needs, then fit the bracket with the relevant nuts, close the door and connect the hose (fig.
  • Page 5 To utilize the full potential of your air conditioner, the tank water is used to increase the cooling power and reduce the noise level and energy consumption of the air conditioner. The water that is used is then expelled from the machine as water vapor through the exhaust hose (it does not go into room).
  • Page 6 Turning on and setting the timer ELECTRICAL CONNECTION Before plugging in check that: • the mains outlet corresponds to the power outlet shown on the rating plate; • the outlet and the mains lead correspond to the power requirements of the appliance ; •...
  • Page 7 If, after having repositioned the drainage tube, the machine still does not start up, the problem might be more complicated (ex.: obstructed ventilation fan) and could require the assistan- ce of a Delonghi Authorized Service Center. , after three minu- with come on . clockwise.
  • Page 8 Anchor the filter to the appliance by atta- ching the two plastic pieces on the filter to the special supports on the air conditioner (see the illustration below). Set the permanent washable filter aside. B. If the dust filter is sufficient: Remove the permanent washable filter from the filter housing and set it aside.
  • Page 9 The electrostatic filter can be purchased in the store as an accessory or at an authorized Delonghi Service Center as a replacement part. Alternatively, the per- manent washable filter included with the appliance may be used in place of the elec- trostatic filter.
  • Page 10 (fig. P), on the bottom of the appliance. 3) Operate the air conditioner for about half an hour. 4) After this, drain out all of the liquid remai- ning in the collection reservoir and rinse thoroughly (fig.
  • Page 11 This appliance contains substances which, if released into the atmosphere, would damage the ozone layer. Care should therefore be taken not to perforate the refrigerant circuit. At the end of its working life, take the air conditioning unit to a special collection Delonghi center. CAUSE •...
  • Page 12 FOR UNITED STATES ONLY: We warrant each DE’LONGHI AIR-CONDITIONER to be free from defects in material and workmanship. Our obligation under this warranty is to provide one year parts and labor free from purchase date, with an additional four (4) years on any part of the sealed system con- sisting of the compressor, evaporator, condenser and factory connected refrigerant tubing.

This manual is also suitable for:

700t

Table of Contents