Dell PowerVault 720N, 740N, and 760N Installation and Troubleshooting Guide
Fans stopped; replace them!
Fault on shelf n
Maintenance mode
Non Maskable interrupt
NFS service not enabled
Parity disk is broken

This message appears if the fan assembly
of the filer stops functioning. Replace the
fan assembly as soon as possible.
n—The PowerVault 700N storage system
enclosure address number. This message
appears when the system detects an error
on one or more Dell PowerVault 700N
storage systems. Check the LEDs of the
specified Dell PowerVault 700N storage
systems to see whether a fan or power
supply needs to be replaced. Replace the
faulty fan or power supply on the Dell
Power-Vault 700N storage system, if
needed.
The system is running in maintenance
mode. Refer to the Dell PowerVault 720N,
740N, and 760N System Administrator and
Command Reference Guide for more
information about maintenance mode.
This message is usually generated by a
correctable (nonfatal) memory error, but
might signal other conditions.
If this message appears repeatedly, it
might indicate a defective memory mod-
ule (DIMM). Refer to the console
messages or to the /etc/messages file for
detailed information.
This message appears only if you have
licensed NFS. NFS service has been dis-
abled either because the system failed to
enable it when it started, or because you
disabled it with the nfs off command.
The parity disk is not operating and the
system is in degraded mode. The solution
depends on whether a hot spare is
installed in the system. Refer to the Dell
PowerVault 720N, 740N, and 760N System
Administrator and Command Reference
Guide for information about replacing a
faulty disk.