4.5 Data Acquisition Parameters

4.5.1 Sampling delay (Warm up time)
The parameter defines an idle period between switching on the excitation and reading
the measurements from the analog and the SDI-12 channels. This option should be
set according to the transducer with the longest warm up time for stable reading.
value of this parameter affects strongly the battery life.
1291,d
d: 0-255 sec
4.5.2 Message transmission period
The parameter defines the message transmission period to the Sigfox network. The
period should be set according to the number of channels selected for acquisition.
Every message contains one channel. The minimum value is 10 minutes in order to
satisfy the limitation of 140 messages per day.
strongly the battery life.
1292,p
p: 1-255 min

4.6 Message Format

The message is in ASCII format and has a fixed length of 12 bytes.
L1
L0
D9
L0, L1: 0-F, HEX, Channel Number
D1-D9: Measurement value
D9: +/-, Sign
D1-D8: Value, can contain a decimal point
IN: 0-1, Digital Input value
Examples:
Channel 1 has the value of -16.7, Digital input is ON.
The Message contents are: 01-000016.71
Channel 2 has the value of 23.3440, Digital input is ON.
The Message contents are: 02+023.34401
Channel 3 has the value of 48546, Digital input is OFF.
The Message contents are: 03+000485460
ADS-260 User Guide
D8
D7
D6
D5
The value of this parameter affects
D4
D3
D2
D1
The
IN
15