Pro-Elec PEL00935 Instructions

Pro-Elec PEL00935 Instructions

Led floodlight with pir

Advertisement

Quick Links

Models: PEL00935, PEL00936, PEL00937
Please read these instructions carefully before use and retain for future
reference.
This floodlights must be installed by a qualified electrician in accordance with current
building and IET wiring regulations (BS7671).
IMPORTANT SAFETY INFORMATION
Do not use PVC cable to connect this floodlight to your wiring supply. Rubberised
cable (type H05RN-F), with three conductors of at least 1.0mm² cross-sectional
area must be used. This product must be connected to Earth.
The front of this floodlight is made of tempered glass, replace if cracked.
LED lamps are extremely bright. To avoid possible damage to the eyes, do not
stare into an LED beam.
In use, avoid touching any external surface of the floodlight, due to the possibility
of high temperatures.
Do not use near flammable materials.
The floodlight must be positioned so that there is at least 1m between the front of
the work light and the surface to be illuminated.
The floodlight has an IP rating of IP44.
It is suitable for use in an ambient temperature between -30°C and +45°C.
LED Floodlight with PIR
& PEL00938
1

Advertisement

loading

Summary of Contents for Pro-Elec PEL00935

  • Page 1 LED Floodlight with PIR Models: PEL00935, PEL00936, PEL00937 & PEL00938 Please read these instructions carefully before use and retain for future reference. This floodlights must be installed by a qualified electrician in accordance with current building and IET wiring regulations (BS7671).
  • Page 2 POSITIONING • This floodlight is suitable for outdoor lighting applications, for domestic use only. • Do not use in areas where an explosive or chemical atmosphere may exist. Do not use in areas where ventilation is restricted. • It is suitable for mounting on plasterboard, wood or masonry surfaces. Highly flammable surfaces such as plastic or polystyrene must not be used.
  • Page 3 Wiring the Floodlight • Ensure that the mains supply is isolated before commencing installation. • A suitable rated connector must be used to connect the lead from the floodlight to the mains supply. • Connect the mains cable to the connector. Ensure that the correct polarities for Live, Neutral and Earth are observed i.e.
  • Page 4 SPECIFICATION PEL00935 PEL00936 PEL00937 PEL00938 Input Voltage 85-260V AC 50/60Hz Nominal luminous flux 750lm 1500lm 2250lm 3750lm Wattage Beam angle 120° 120° 120° 120° Dimmable Nominal lifetime of the lamp 20,000h 20,000h 20,000h 20,000h Number of switching 15,000 15,000 15,000...