Ariston DEOS s Series User Manual page 19

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
IN CASE THE DEHUMIDIFIER MALFUNCTIONS
BEFORE CONTACTING THE TECHNICAL ASSISTANCE CENTRE, PERFORM THE FOLLOWING CHECKS:
PROBLEM
The appliance does not start by pressing
the ON/OFF button.
The appliance is not able to dehumidify
the room enough.
The appliance is very noisy.
'P1' appears on the display.
'P2' appears on the display.
'E1' appears on the display.
'E2' appears on the display.
Type of appliance
Supplier brand
(1)
Dehumidifi cation
(1)
Power consumption
(1)
Sound pressure
Type of refrigerant
(2)
GWP
Operating temperature
Tank capacity
Power supply and no. of phases
Type of compressor
Maximum air fl ow rate
Standard refrigerant charge
Dimensions
Weight (net/gross)
(1) Relative to operation at 30°C and 80% relative humidity.
(2) Refrigerant loss contributes to climate change. In case of their release into the atmosphere, refrigerants with lower global warming
potential (GWP) have less impact on global warming compared to refrigerants with a higher GWP. This appliance contains a refriger-
ant fl uid with a GWP of 1,300. In other words, if 1 kg of this refrigerant fl uid were released into the atmosphere, the impact on global
warming would be 1,300 times greater compared to 1 kg of CO
attempt to intervene on the refrigerant circuit or dismantle the product. In case of need, please contact a qualifi ed professional.
CAUSE
1) The plug is not properly inserted.
2) The main switch is not properly inserted.
3) The tank full indicator light is lit.
4) The tank is either full or not properly in-
serted.
1) The air inlet or outlet are obstructed (by
curtains, objects, walls, etc.).
2) The set humidity level is not low enough.
3) The windows and doors of the room are
not closed.
4) The room temperature is either too low
(lower than 5°C) or too high (above 35°C).
5) The air fi lter is clogged.
1) The air fi lter is clogged.
2) The appliance is inclined.
3) The appliance is resting on a non-fl at sur-
face.
Anti-frost function active.
Tank full.
The humidity sensor is disconnected or has
short-circuited.
The temperature sensor is disconnected or
has short-circuited.
PRODUCT TECHNICAL SHEET
SOLUTION
1) Insert the plug correctly.
2) Check the main switch.
3) Empty the tank.
4) Put the tank properly back into place.
1) Free the air inlet and outlet.
2) Appropriately adjust the humidity level.
3) Close all windows and doors.
5) Clean the air fi lter.
1) Clean the air fi lter.
2) 3) Reposition the appliance.
Wait until the defrosting function ends. 'P1' will dis-
appear automatically.
Empty the tank and put it correctly back in place.
Contact the technical assistance service.
Contact the technical assistance service.
DEOS 16s
litres/day
W
dB(A)
kgCO2 eq.
°C
litres
Hz - V - Ph
50-230-1
Rotativo
m3/h
kg
mm
345x501x257
kg
12,1/13,6
, over a period of 100 years. In no case whatsoever must the user
2
Dehumidifi er
ARISTON
DEOS 20s
16
20
312
379
42
42
R134A
R134A
1430
1430
5/35
5/35
3
50-230-1
Rotativo
150
150
0,12
0,13
345x501x257
12,2/13,7
GB
3
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Deos 20sDeos 16s

Table of Contents