Download Print this page

Sealey sa19/S.V2 Instructions page 2

Air operated angle head sander

Advertisement

3. INTRODUCTION
Lightweight and versatile sanding tool suitable for use with SA720 mini sanding pads or 3M® bristle pads and 3M® backing pads. 97° Angle
head with gearless drive gives optimum performance. fitted with safety release trigger control and variable speed adjustment.
Includes backing pad and wrench.
4. SPECIFICATION
Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SA19/S.V2
Pad Size: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ø50mm
thread Size: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4"unc
free Speed:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18000rpm
Air consumption: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10cfm
operating Pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90psi
Inlet Size:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4"BSP
Weight:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.6kg
noise Power/Pressure: . . . . . . . . . . . . . . . . . . 98dB(A) / 87dB(A)
Vibration/uncertainty: . . . . . . . . . . . . . . . . . . . . . .2.29 / 0.72m/s²
5. OPERATION
WARNING! Ensure you have read understood and follow the safety instructions in section 1.
5.1.
Screw the sanding disk carrier onto the shaft and tighten with the spanner provided.
5.2.
Attach a mini sanding disc by screwing it into the centre of the carrier.
5.3.
Attach the tool to the air supply, section 2.
5.4.
to operate the sander, squeeze the trigger.
NOTE: The air regulator/speed control may be used as a means of throttle control. See fig.2.
6. MAINTENANCE
WARNING! Disconnect the sander from the air supply before changing accessories, servicing or performing any maintenance.
6.1.
Keep the sander oiled for optimum performance.
Lubricate daily with a good grade of air oil such as Sealey Ato/500 or Ato/1000. If no air tool oil is used, a teaspoon of oil can be
poured into the tool's air inlet, or into the hose at the nearest connection to the air supply. then run the sander for a short time.
6.2.
Always check the rPM rating of any accessory to ensure it is compatible with the rPM of this sander.
Note: the following external factors may cause loss of power and effect sander performance:
The air system.
reduced compressor output, excessive drain on the air line, moisture or restrictions in air pipes or in the use of hose connection
having the improper size. correct the condition accordingly.
The tool.
Grit or gum deposits in the tool. correct by cleaning the air strainer and flushing out the tool with gum solvent oil or an equal mixture of
SAE no.10 oil and kerosene.
If despite taking action as for above situations the tool function is impaired, contact your local Sealey service agent for advice.
© Jack Sealey Limited
fig.2
Original Language Version
SA19/S.V2
Issue:4 - 12/02/18

Advertisement