TAKING CARE OF UNEXPECTED PROBLEMS
NO POWER AT THE DC TERMINALS
Possible Cause
DC circuit protector OFF.
Faulty generator.
ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR FLASHING
Possible Cause
CO concentration around the
generator is high.
ENGINE AUTOMATICALLY STOP AND THE FAULT/CO SENSOR LIFE
INDICATOR FLASHING
Possible Cause
CO sensor malfunction.
CO sensor may have reached the end
of its useful lifespan (see page 27).
FAULT/CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING THE
ENGINE
Possible Cause
CO sensor may reach the end of its
useful lifespan (see page 27).
86
Correction
Turn DC circuit protector ON
(see page 32).
Take the generator to an authorized
Honda Power Equipment dealer, or
refer to the shop manual.
Correction
Review the location of the generator,
and place it in a well-ventilated
outdoor location (see page 26).
When the engine is stopped
automatically by CO-MINDER, press
the CO-MINDER reset button to restart
the engine (see page 49).
Correction
If the engine cannot be started and
the CO ALARM indicator flashes, even
if the location of the generator has
changed, there may be a CO-MINDER
malfunction. Consult an authorized
Honda Power Equipment dealer.
Consult an authorized Honda Power
Equipment dealer.
Correction
Consult an authorized Honda Power
Equipment dealer for replacement.