Everet EVP412 User Manual

Everet EVP412 User Manual

12x uhd 4k ptz video camera
Hide thumbs Also See for EVP412:

Advertisement

Quick Links

EVERET EVP412
12x UHD 4K PTZ Video Camera 
User Manual 
 
 
Version V1.0 
(English) 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EVP412 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Everet EVP412

  • Page 1 EVERET EVP412 12x UHD 4K PTZ Video Camera  User Manual      Version V1.0  (English) ...
  • Page 2: Table Of Contents

    CONTENT    SAFETY GUIDES 2  PACKING LIST 3  QUICK START 3  1. Check all cable connections before power on. 3  2. Dial Switch Settings (at the bottom of the camera) 4  PRODUCT HIGHLIGHTS 5  TECHNICAL SPECIFICATIONS 6  CAMERA INTERFACE 8  CAMERA DIMENSIONS 8 ...
  • Page 3: Safety Guides

    Avoid stress, vibration and damp during transportation, storage and installation.    Do not detatch the camera housing and cover. For any service, please contact authorized    Everet technicians.  Video cable and control cable should be individually shielded, and cannot be substituted    with other cables. ...
  • Page 4: Packing List

    PACKING LIST  Check all bellow items when open the package:    Camera  1  Power Adapter  1  Power Cable  1  RS232 Control Cable  1  USB 3.0 Cable  1  Remote Controller  1    QUICK START   Check all cable connections before power on.    ...
  • Page 5: Dial Switch Settings (At The Bottom Of The Camera)

    2.  Dial Switch Settings (at the bottom of the camera)  Dial Switch(ARM)     SW-1  SW-2  Instruction  1  OFF  OFF  Updating mode  2  ON  OFF  Debugging mode  3  OFF  ON  Undefined  4  ON  ON  Working mode  Dial Switch     SW-3  SW-4  Instruction ...
  • Page 6: Product Highlights

    2  ON  OFF  Working mode  3  OFF  ON  Updating mode  4  ON  ON  Undefined  PRODUCT HIGHLIGHTS   ● Sony Adopts most advanced ISP, 1/2.5 inch 8.5MP sensor, providing 3840x2160 p30  Ultra HD video resolution  ● 4K wide angle optical lens: 12x optical zoom and 2x digital zoom , with 72.5 degree  field of view;  ...
  • Page 7: Technical Specifications

    TECHNICAL SPECIFICATIONS   Video Format  HDMI  3840*2160P30/25  1920*1080P60/50/30/25/59.94/29.97/24  1920*1080I60/50/59.94  1280*720P60/50/30/25/59.94/29.97  SDI  1920*1080P60/50/30/25/59.94/29.97/24  1920*1080I60/50/59.94  1280*720P60/50/30/25/59.94/29.97  USB  1920*1080P60/50/30/25(USB3.0)  1280*720P60/50/30(USB3.0)  1280*720P25(USB3.0 & USB2.0)  1024*576P30(USB3.0 & USB2.0)  960*540P30(USB2.0)  640*360P30(USB2.0)  512*288P30(USB2.0)  IP  3840*2160@1~30 / 1920*1080@1~30 (Main Stream)  1280*720@1~30 / 1027*576@1~30 / 640*360@1~30 (Sub stream)  Video Interface  HDMI, 3G-SDI, RJ45, USB3.0 ...
  • Page 8 POE  Supported  Daisy Chain  Support RS232 serial daisy chain  Minimum Lux  0.1 lux  White Balance  Auto/Indoor/Outdoor/Manual/Auto/Sodium Lamp Auto/Sodium Lamp  Exposure  Auto/Manual/Bright/Shutter/Iris  Focus  Auto / Manual  Iris  Auto / Manual  Electric Shutter  Auto / Manual  Gamma  Supported  WDR  Supported  BLC  Supported  2D/ 3D Noise ...
  • Page 9: Camera Interface

    CAMERA INTERFACE​     1.Camera Lens    6. Tripod Screw Hole  10. HDMI port  2.Camera Base  7. Installation Hole   11.3G-SDI port  3.IR Receiver Panel  8. RS232 control port (input)  12, USB port  4.Power Indicator Light    9. RS232 control port(output)  13, RJ45 port ...
  • Page 10: Ir Remote Controller

    POWER  Under normal working mode, short press  IR REMOTE CONTROLLER   POWER key, to enter standby mode;  Press it again, the camera will do  self-configuration, then go back to HOME  position.  It will go to preset position if power on model  has been set before. ...
  • Page 11 FOCUS KEY ( ON THE LEFT)  Manual focus, only valid under manual focus  model.  ZOOM KEY( ON THE RIGHT SIDE)  Set the zoom rate  NAVIGATE KEY: UP/DOWN/LEFT/RIGHT  Under working mode, use navigate key to set  the pan tilt, and select menu when enter OSD.  OK /HOME KEY ...
  • Page 12: Visca In(Rs232 Port)

      VISCA IN(RS232 PORT)     No.  V_IN  V_OUT  1  DTR  DTR  2  DSR  DSR  3  TXD  TXD  4  GND  GND  5  RXD  RXD  6  A    7  IR OUT    8  B    VISCA IN  RS485  6  A (+)  7 ...
  • Page 13 VISCA NETWORK SETUP:    SERIAL PORT CONFIGURATION:   Parameter  Value  Parameter  Value  Baud rate  2400/4800/9600/115 Stop Bit  1bit  200  Start Bit  1 bit  Check Bit  None  Date Bit  8 bit        12  WWW.EVERETIMAGING.COM ...
  • Page 14: Visca Protocol

    VISCA PROTOCOL   PART1 CAMERA RETURN COMMAND  Ack / Completion Message     Command  Note  Packet  ACK  z0 41 FF  Returned when the command is accepted.  Completion  z0 51 FF  Returned when the command has been executed.  z = camera address+8   ...
  • Page 15 OFF  8x 01 04 06 03 FF  Combine Mode  81 01 04 36 00 FF  Combine with optical zoom control  Separate Mode  81 01 04 36 01 FF  Separate with optical zoom control  Stop  81 01 04 06 00 FF  Enable In separate mode ...
  • Page 16 Down  8x 01 04 03 03 FF  Direct  8x 01 04 43 00 00 0p 0q FF  pq: R Gain (0~0xFF)  CAM_Bgain  Reset  8x 01 04 04 00 FF  Manual Control of B Gain  Up  8x 01 04 04 02 FF  Down ...
  • Page 17 CAM_WDR  On  8x 01 04 3D 02 FF  Exposure Compensation ON/OFF  Off  8x 01 04 3D 03 FF  Direct  8x 01 04 2D pq FF  pq: ExpComp Position (0~0x6)  CAM_BackLight(BLC)  On  8x 01 04 33 02 FF  BackLight On  Off  8x 01 04 33 03 FF ...
  • Page 18 CAM_Gamma  Gamma set  81 01 04 5B 0p FF  P:Gamma NO. (0~4)  CAM_MountMode  UP  8x 01 04 A4 02 FF  Mount Up  Down  8x 01 04 A4 03 FF  Mount Down  CAM_ColorGain  Direct  8x 01 04 49 00 00 00 0p FF  (0~0x0E) ...
  • Page 19 DHCP control  DHCP off  8x 01 04 AE 00 FF  DHCP off  DHCP on  8x 01 04 AE 01 FF  DHCP on  Mainstream  resolution  8x 01 04 C2 00 0p 0q 0r 0s 0m  pqrs : Column(x size)  0n 0x 0y FF  mnxy: Line (y size) ...
  • Page 20: Part3 Camera Control Command

    Off  8x 01 06 08 03 FF  On/Off  8x 01 06 08 10 FF  Pan_tiltDrive  Up  8x 01 06 01 VV WW 03 01 FF  VV: Pan speed 0x01 (low speed) to 0x18  (high speed)  WW: Tilt speed 0x01 (low speed) to 0x14  Down ...
  • Page 21 CAM_WBModeInq  8x 09 04 35 FF  y0 50 00 FF  Auto  y0 50 01 FF  Indoor mode  y0 50 02 FF  Outdoor mode  y0 50 03 FF  OnePush mode  y0 50 04 FF  ATW  y0 50 05 FF  Manual  CAM_RGainInq  8x 09 04 43 FF ...
  • Page 22 CAM_GATEWAYInq  8x 09 04 AD FF  y0 50 0p 0p 0q 0q 0r 0r 0s 0s     FF  CAM_FlareModeInq  8x 09 04 B6 FF  y0 50 pp FF     CAM_FlareBrightMode 8x 09 04 B7 FF  y0 50 pp FF     Inq ...
  • Page 23: Visca Pan Tilt Absolute Position Value

    VISCA PAN TILT ABSOLUTE POSITION VALUE  Pan Angle  VISCA Value  Tilt Angle  VISCA Value  -170  0xF670  -30  0xFE50  -135  0xF868  0  0x0000  -90  0xFAF0  30  0x01B0  -45  0xFD78  60  0x0360  0  0x0000  90  0x510  45  0x0288        90  0x0510    ...
  • Page 24: Pelco-D Protocol Command List

    16  25  16  59  17  32  17  69  18  38  18  80  19  45        20  58        21  75        22  88        23  105        24  120        PELCO-D PROTOCOL COMMAND LIST    ...
  • Page 25: Pelco-P Protocol Command List

    Query Pan  0Xff  Address  0x00  0x51  0x00  0x00  SUM  Position  Query Pan  0Xff  Address  0x00  0x59  Value High  Value Low Byte  SUM  Position  Byte  Response  Query Tilt  0Xff  Address  0x00  0x53  0x00  0x00  SUM  Position  Query Tilt  0Xff  Address  0x00  0x5B ...
  • Page 26: Osd Menu

    Call Preset  0xA0  Address  0x00  0x07  0x00  Preset ID  0xAF  XOR  Query Pan  0xA0  Address  0x00  0x51  0x00  0x00  0xAF  XOR  Position  Query Pan  0xA0  Address  0x00  0x59  Value High Byte  Value Low  0xAF  XOR  Position  Byte  Response  Query Tilt  0xA0 ...
  • Page 27 5. OSD Menu Setting List    SYSTEM  PROTOCOL  Optional item:VISCA、PELCO-P、PELCO-D  Default:VISCA  ADDRESS  VISCA:1~7  PELCO-P/D:1~255  Default:1  BAUD RATE  Optional item:2400、4800、9600、115200  Default:9600  PTL LOCK  Protocol lock: once set, above protocol setting  Default:OFF  will be locked  RS485  RS485 ON/OFF  Default:OFF  VISCA  To select VISCA sources  Default: ...
  • Page 28 B GAIN  Blue gain level:0~255 , only valid under manual  Default:AUTO  white balance mode  FLICK  Anti-Flicker setting:50/60HZ, to reduce the  Default:50HZ  video flicker  DZOOM  Turn on/off digital zoom (2x digital zoome)  Default:OFF  FOCUS  Select focus mode  Default:AUTO     QUALITY  2D NR  2D noise reduction: the bigger value, the less ...
  • Page 29 1080P59.94  720P25  mode does not support  menu switching, when  1080P50  1080P60  switch to 4K model, menu  will be existed  1080I59.94  1080P30  automatically.  1080I50  720P60  1080P29.97  720P30  1080P25  1080I60  720P59.94  1080P24                   IP  DHCP  ON/OFF ...
  • Page 30: Ip Address Setting

    ARM VER  ARM firmware version  FPGA VER  FPGA firmware version  CAM VER  Camera version  RELEASE  Software release date     IP ADDRESS SETTING    Default your camera is set to DHCP OFF with IP adress 192.168.1.188 (see label at the bottom)  Please check your IP Address settings for using it in your network.
  • Page 31: Web Settings

    WEB SETTINGS  1. Login  Run browser, input IP address( default IP address is 192.168.1.188) to enter login interface  Input admin and password to login as following:  (Default admin: admin Default password: admin)         2. Parameter Setting  Click “Setting” to enter into the settings interface as following:    ...
  • Page 32     Image Parameter​ : to set focus, exposure, white balance, image, image quality, noise-reduction    Focus​ including focus mode, default focal distance, digital zoom etc        Exposure​ includes exposure mode, shutter speed, gain, iris, brightness, and anti-flicker.   ...
  • Page 33   Image Setting​ includes brightness, sharpness, contrast, saturation        Noise reduction​ includes 2D/3D reduction. There is an on/off option for 2D, and off/auto/1~4 options.         Ethernet​ includes DHCP mode, IP address, subnet mask, default gateway, http port, web port, main  stream port, sub stream port. ...
  • Page 34 How to update:  Click “select file” icon, to open dialog box, select to open the file      Click “upgrade” to start the upgrade process. Only use upgrade files from everet.eu support website.        DO NOT power off ​ o r other actions during the upgrade process, reboot the camera when the upgrade ...
  • Page 35 Then login into web frontend and select “reset all” to reset the camera completely.    Reboot:​ Reboot ISP part of camera         Account Setting​ : is used for setting your camera account and password  First Input the accountname, then input password twice, click ok to finish settings.   ...
  • Page 36: Using Vlc To View Rtsp/Rtmp Video

    USING VLC TO VIEW RTSP/RTMP VIDEO  Default RTSP main streaming address: rtsp://192.168.1.188/stream/main  Default RTSP sub streaming address: rtsp://192.168.1.188/stream/sub  Default RTMP main streaming address: rtmp://192.168.1.188:1935/app/rtmpstream0  Default RTMP sub streaming address:rtmp://192.168.1.188:1935/app/rtmpstream1    1. Run VLC Media Player.  2. Select Media > network stream, to show “open media” interface.  3.
  • Page 37: How To Use Visca Over Ip

    HOW TO USE VISCA OVER IP  VISCA Command  It means commands from controller to peripheral equipment, when peripheral equipment receives  commands, then return ACK. When commands executed, will return complete message.  For different commands, camera will return different message.  VISCA Inquiry  It means inquiry from controller to peripheral equipment when peripheral equipment receives this ...
  • Page 38 VISCA device  0x01  0x20  Stores the VISCA device setting  setting  command.  command  Control  0x02  0x00  Stores the control command.  command  Control reply  0x02  0x01  Stores the reply for the control  command.  Payload length  Valid data length in Payload (1~16), is command length.  For example, when valid data length is 16 byte ...
  • Page 39          Delivery confirmation  VISCA over IP uses UDP as transmission communication protocol, UDP communication message  transmission is not stable. It is necessary to confirm delivery and resent in application.  Generally, when controller sends a command to peripheral equipment, controller will wait for the  return message then send the next command, we can detect and confirm if the peripheral equipment ...
  • Page 40 Sequence chart as specified        Sequence chart when command lost Sequence chart when returned  message lost    Note: Do not set IP address, subnet mask, gateway parameter in VISCA over IP command.              ...

Table of Contents