1. Pull the battery pack unlocking button in the direc-
tion of the battery pack.
Illustration K
2. Press the battery pack unlocking button to unlock
the battery pack.
3. Remove the battery pack from the device.
Ending operation
1. Remove the battery pack from the device (see
Chapter Removing the battery pack).
2. Clean the device (see Chapter Cleaning the de-
vice).

Transport and storage

1. Switch off the device.
2. Remove the battery pack, see Chapter Removing
the battery pack.
3. Removing the blower pipe.
Illustration L
a Turn the blower pipe until it can be released from
the pipe.
b Remove the blower pipe.
4. Removing the blower pipe nozzle.
Illustration L
a Turn the blower pipe nozzle until it can be re-
leased from the blower pipe.
b Remove the blower pipe nozzle.

Care and service

The device is maintenance-free.
Cleaning the device
WARNING
Uncontrolled startup
Risk of injury
Remove the battery pack from the device during work
breaks and before carrying out any service or care work.
ATTENTION
Incorrect cleaning
Damage to the device
Clean the device with a damp cloth.
Do not use solvent-based cleaning agents.
Do not immerse the device in water.
Do not clean the device with a hose or high-pressure
water jet.
1. Switch off the device.
2. Remove the battery pack (see Chapter Removing
the battery pack).
3. Clean the exterior of the device with a soft, dry cloth
or with a brush.
Illustration M
Changing the bellows
WARNING
Uncontrolled startup
Risk of injury
Remove the battery pack from the device during work
breaks and before carrying out any service or care work.
WARNING
Risk of injury due to incompletely assembled de-
vice
Only operate the appliance once it is fully assembled
and functional.
1. Switch off the device.
2. Remove the battery pack (see Chapter Removing
the battery pack).
3. Remove the bellows.
Illustration N
a Loosen and remove the screws of the clamp on
the connection pipe using the supplied assembly
tool.
b Remove the clamp.
c Remove the connection pipe.
d Loosen and remove the screws of the clamp on
the casing using the assembly tool provided.
e Remove the clamp.
f Remove the bellows from the casing.
4. Mount the new bellows on the casing.
a Push one end of the bellows over the casing pipe
so that the raised burr on the pipe fits securely in-
to the slot on the bellows.
Illustration B
b Insert the sheathed cable into the recess in the
pipe clamp.
c Fit the parts of the pipe clamp on the pipe above
and below the bellows so that the sheathed cable
is not pinched.
d Insert a screw in the pipe clamp on the side that
is closest to the device and tighten with the sup-
plied assembly tool.
Illustration C
e Insert the second screw in the other side of the
pipe clamp and tighten with the assembly tool
provided.
5. Mount the connection pipe on the new bellows.
a Push the connection pipe into the bellows so that
the raised burr on the pipe fits securely into the
slot on the bellows.
Illustration D
b Insert the sheathed cable into the recess in the
pipe clamp.
c Fit the parts of the pipe clamp on the pipe above
and below the bellows so that the sheathed cable
is not pinched.
d Insert a screw in the pipe clamp on the side that
is closest to the device and tighten with the sup-
plied assembly tool.
Illustration E
e Insert the second screw in the other side of the
pipe clamp and tighten with the assembly tool
provided.
6. Mount the blower pipe nozzle.
a Slide the cutouts on the nozzle over the lugs on
the blower pipe.
Illustration F
b Turn the nozzle so that the two arrows point to-
wards each other.
The nozzle is latched in position.
7. Mount the blower pipe.
a Slide the cutouts on the blower pipe over the lugs
on the device.
Illustration F
b Turn the blower pipe so that the two arrows point
towards each other.
The blower pipe is latched in position.