Page 1
Quick start guide to set Max and Min Alert Temperatures Model No. DGT-310 Digital Thermocouple Grill Thermometer Set Maximum Temperature – 1. Press MAX button to view the Maximum Alert Temperature 2. While viewing the MAX temperature, Press and hold MAX button for 2 seconds. MAX will flash on the thermometer LCD 3.
Page 2
Digital Thermocouple Grill Thermometer Instructions Model # DGT-310 C/F & RESET buttons inside Battery Compartment Thermometer buttons POWER On/Off (BACKLIGHT) Up /MAX Down /MIN C / F (RE-CALIBRATION) RESET...
INSTALLING BATTERIES Use a screwdriver to remove the screw of the battery door. Insert two AAA batteries noting the polarity. The (-) side goes on the spring. Install the battery cover and secure with screw. Do not over tighten. To keep your thermometer water-resistant, make sure the rubber gasket is lined up with the battery compartment Note: “The default temperature reading for this thermometer is in °F.
Page 4
Press and hold 3 seconds to turn off the thermometer #2. UP /MAXIMUM TEMPERATURE ALERT Memory Set (Set at the factory at 400 F) Press MAX once to show Maximum Temperature Alert screen for 5 seconds and then it will go back to Current Temperature Screen. ...
Page 5
Minimum Temperature Alert will be automatically set after 10 seconds of not pressing any buttons. #4. TURN ON MAXIMUM, MINIMUM TEMPERATURE ALERT On Current Temperature screen, press & hold UP/MAX button for 2 seconds to turn on Maximum Temperature Alert. The icon will be shown.
Page 6
show ‘HI’ and non-stop beeping. #5. USER Re-Calibration of Thermometer Make ice bath with 3 parts ice and 1 part cold water Insert the probe tip into center of ice bath. Press and hold the C/F button inside the battery compartment for 5 seconds to enter CALIBRATION mode CAL ...
#7. RESET Press RESET button inside the battery compartment of the unit when abnormal operation occurs such as the unit continues to beep despite turning off the alerts. If abnormal operation persists, remove the batteries and re-insert. #8. “ HI” Temperature Warning ...
Page 8
Operating Range : 32°F to 842°F / 0°C to +450°C Display Range : 32°F to 842°F / 0°C to +450°C Power : 2 x AAA batteries (Included) CARE OF YOUR PRODUCT Don’t touch the probe tip with bare fingers after use, to avoid burning fingers. Although this thermometer is water resistance, do not submerge the unit into water.
Page 9
Hours: Weekdays 8:30 AM - 4:30 PM Do not send any parts or product to Maverick without obtaining a Return Authorization Number and instructions. This warranty is VOID if instructions for use are not followed; for accidental damage; for commercial use;...