Meridian Series
Reach-Ins Service and Installation Manual
®
WIRING DIAGRAM MERIDIAN FREEZER 115/208-230v
BLUE
YELLOW
BROWN
WHITE
BLACK
WHITE
PURPLE
BROWN
YELLOW
BLACK
CR
COMPRESSOR RELAY
PSS
POWER SUPPLY SWITCH
HLS
HIGH LIMIT SAFETY
COND
CONDENSING UNIT
ELS
EXTERNAL LIGHT SWITCH
LPC
LOW PRESSURE CONTROL
DS
DOOR SWITCH
DLFD
DEFROST LIMIT FAN DELAY
NOTE: Display lights are on "G" models only. Solenoid valve on remote
models only. Power cord may or may not be provided. Power switch used
with electronic controls only.
18
For customer service, call (800) 733-8829 or (800) 733-8948, Fax (989) 773-3210, www.delfield.com
YELLOW
WHITE
BROWN
BROWN
THERMOSTAT
PURPLE
BLUE
BLACK