Download Print this page
Sealey sac5020e110v.v3 Manual

Sealey sac5020e110v.v3 Manual

50ltr direct drive compressor 2hp 110v

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. SaFETY
1.1.
ELECTRICaL SaFETY
WaRNING! It is the responsibility of the owner and the operator to read, understand and comply with the following: You must check
all electrical products before use to ensure that they are safe. You must inspect power cables, plugs, sockets and any other connectors
for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A
Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual
Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is
not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your
Sealey stockist. You must also read and understand the following instructions concerning electrical safety:
1.1.1.
The Electricity at Work act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2.
The Health & Safety at Work act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2. and
use a Portable Appliance Tester.
1.1.4.
Ensure that cables are always protected against short circuit and overload.
1.1.5.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none are loose.
1.1.6.
Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the
correct fuse.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item
8
repaired or replaced by a qualified electrician. When a BS EN 60309 plug is damaged, cut the
cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions:
a) Connect the GREEN/YELLOW earth wire to the earth terminal.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) after wiring, check that there are no bare wires, that all wires have been connected
correctly, that the cable outer insulation extends beyond the cable restraint and that the
restraint is tight.
NOTE: If using a transformer to supply the compressor, it must be rated at a minimum of
2kVa to allow the compressor to run efficiently.
1.2.
GENERaL SaFETY
Familiarise yourself with the application and limitations of the compressor.
9
99 Ensure the compressor is in good order and condition before use. If in any doubt do not use the
9
9
unit and contact an electrician/service agent.
WaRNING! Compressor must only be serviced by an authorised agent. DO NOT tamper with, or attempt to adjust, pressure
switch or safety valve.
99 Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been
9
9
vented.
99 maintain the compressor in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts may be
9
9
dangerous and will invalidate your warranty.
99 Read the instructions relating to any accessory to be used with this compressor. Ensure the safe working pressure of any air appliance
9
9
used exceeds compressors output pressure.
If using a spray a gun, check that the area selected for spraying is provided with an air change/ventilation system.
9
99 Ensure the air supply valve is turned off before disconnecting the air supply hose.
9
9
9 9 To move the compressor use the handle only. maintain unit's centre of gravity when lifting. DO NOT attempt to lift or move the
9
9
compressor by any other means.
99 Use the compressor in a well ventilated area and ensure it is placed on a firm surface.
9
9
Keep tools and other items away from the compressor when it is in use, and keep area clean and clear of unnecessary items.
9
9 9 Ensure the air hose is not tangled, twisted or pinched.
9
9
© Jack Sealey Limited
50LTR DIRECT DRIVE COMPRESSOR 2HP 110V
mODEL NO:
Wear ear
Ensure oil level
WaRNING:
protection
is correct before
High Voltage
first use
Original Language Version
SaC5020E110V.V3
WaRNING:
WaRNING:
Hot surface
Automatic
start up
Indoor use only
DO NOT open
the air cock
before an air
hose is attached
SAC5020E110V.V3 | Issue:1 14/06/19

Advertisement

loading

Summary of Contents for Sealey sac5020e110v.v3

  • Page 1 SaC5020E110V.V3 mODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Specification

    Pump head directly coupled to heavy-duty induction motor for reliable and smooth operation. Precision welded receiver tank manufactured to meet Pressure Vessel Directive. Fitted with fully automatic pressure cut-out switch and twin gauges displaying tank and working pressures. 3. SPECIFICaTION model no ..........SAC5020E110V.V3 motor output ..............2hp Supply ................110V Air displacement .........6.3cfm/178ltr/min...
  • Page 3: Safety Features

    Alternatively, wash in soapy water, rinse and dry. DO NOT operate the compressor without the filter as foreign bodies or dust could seriously damage the pump. c) Check for oil leaks Original Language Version SAC5020E110V.V3 | Issue:1 14/06/19 © Jack Sealey Limited...
  • Page 4: Troubleshooting

    Replace the drain bolt and refill with fresh oil through the filler aperture. DO NOT overfill. Replace plug (fig.2A). Recommended oil for compressors, Suitable for room temperatures ranging from +5ºC to +25ºC. SEALEY CPO or equivalent SAE 40 compressor oil.
  • Page 5: Weee Regulations

    Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7aR 01284 757500 01284 703534 sales@sealey.co.uk...