Whitehall Best-Care Corterra WH3776 Installation, Operation And Maintenance Manual page 2

Ligature resistant corner basin ada compliant

Advertisement

Instructions for Operation and Care of Best-Care WH3776
Important: Some options may slightly alter installation. To ensure proper installation
review the Manual thoroughly and verify rough-ins before beginning any work. File this
Manual with the owner or maintenance personnel upon completion of installation.
Industry standard wall backing, for wall hung fixtures, is required. Installer provided wall
anchors and wall anchoring hardware with a minimum Pull-Out Force of 1000 pounds
(lbs) per anchor for appropriate wall construction.
ANSI, UFAS or ADA compliance is subject to the interpretation and requirements of the
local code authority and is the responsibility of the installer for verification.
Single Temp Valve Assembly: Recommended working water pressure is 30 PSI (2.07
bars) minimum to 100 PSI (6.89 bars) maximum. Maximum temperature is 130°F
(54.4°C). Maximum outlet temperature recommended is 105°F (40.6°C). Valve
assembly must be drained prior to being subjected to freezing temperatures. A
checkstop is provided with this valve assembly.
T/P Mixing Valve Assembly: Recommended working water pressure is 30 PSI (2.07
bars) minimum to 100 PSI (6.89 bars) maximum. Maximum hot water temperature is
180°F (82°C). Temperature adjustment range is 85°F-115°F (29°C-46°C). Minimum hot
water supply temperature must be 5°F (3°C) above desired set temperature. Valve
assembly must be drained prior to being subjected to freezing temperatures. The valve
assembly has checks integral to the inlets however, angle stops are to be provided by
the installer.
Prior to installation, supply lines must be flushed of all foreign material such as pipe
dope, chips, or solder. Debris or foreign material in water supply may damage valve.
Teflon tape is recommended on threaded connections where applicable to reduce the
possibility of leaks.
Provide 110-120 VAC/60Hz/3A (MAX) electrical receptacle for factory supplied
120VAC/9VDC, 100mA plug-in transformer.
NOTE: Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth
grounded per N.E.C. (National Electrical Code).
Upon receiving, verify count and inspect packaging for obvious signs of damage or
missing containers. If there are any issues upon receiving make note on bill of lading and
report to carrier and manufacturer promptly. Remove fixture assemblies from packaging
and ensure all parts are present before beginning installation. Do not discard packaging
until all parts have been accounted for. Refer to Acorn terms, conditions of sales and
warranty for more information.