Instructions for Operation and Care of Best-Care WH3776
SENSOR OPERATION & CONNECTIONS
-SO Sensor Operation
Range Adjustment
1. Make sure Power Supply is disconnected from
Sensor and make short circuit on red wires.
See DETAIL A.
2. Connect Power Supply to Sensor. Red light should
be flashing.
3. Move hand in front of sensor to distance of 2" to 4"
within 5 seconds and wait until red light flashes
quickly.
4. Move hand to desired sensing distance.
See DETAIL B.
5. Hold hand at desired sensing distance until red light
stops flashing and Solenoid activates.
See DETAIL C.
-SO Sensor Operation or
-PPZ Programmable Piezo Pushbutton
TRANSFORMER
RED
BLUE
SOLENOID VALVE
12
WHITEHALL MANUFACTURING • P .O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
-SO SENSOR
-PPZ PUSHBUTTON
Transformer must
RED
BLUE
be plugged into a
GFI protected
circuit. Fixture must
be earth grounded
per N.E.C. or
applicable codes.
Jumper
DETAIL A
By Others
DETAIL B
DETAIL C