Summary of Contents for Cross Technologies 2117-9395
Page 1
10MHZ Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
Page 2
All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages.
Page 3
9.30-9.50 GHz Up, 9.30-9.50 GHz Down 1.0 General The 2117-9395 Up/Downconverter converts 2.00 - 2.20 GHz to 9.30 - 9.50 GHz and 9.30-9.50 GHz to 1.60 - 1.80 GHz, with non-inverting spectrums. Front panel LEDs provide indication of DC Power, External 10 MHz, and PLL Alarm.
Page 4
1.2 Technical Characteristics TABLE 1.0 2117-9395 Up/Downconverter Specifications* EQUIPMENT SPECIFICATIONS* SPECIFICATIONS* I I nput Input Characteristics UP, C DOWN, C 50Ω/14 dB 50Ω/14 dB Impedance/Return Loss Frequency 2.00-2.20 GHz 9.30-9.50 GHz Noise Figure, Max. 20 dB @ max gain 25 dB @ max gain...
Page 5
2.0 Installation 2.1 Mechanical - The 2117-9395 consists of one RF PCB housed in a 1 RU (1 3/4 inch high) by 14 inch deep chassis. A switching, ± 12, +24, +5 VDC power supply provides power for the assemblies. The 2117-9395 can be secured to a rack using the 4 holes on the front panel.
Page 6
Lights YELLOW when external Lights RED when PLL Lights GREEN when DC voltage is 10MHz reference is active. comes out of lock. present from AC power supply. 10MHZ ALARM POWER FIGURE 2.2 2117-9395 Front Panel Controls and Indicators 2117-9395_Manual Page 6 09/12/19...
Page 7
Alarm Relay: Normally Open Plus DC input Not Used Shell Ground Alarm Relay: Normally Closed FIGURE 2.1 2117-9395 Rear Panel I/Oʼs FIGURE 2.3 2117-9395 DC1 Pinouts TABLE 2.2 Available Options P48 = 48 VDC Nominal 36-72 VDC, 2.5A max. Redundant AC Power Supply Available Connector Options 50Ω...
Page 8
2.4 Installation / Operation 2.4.2 Installing and Operating the 2117-9395 Downconverter 1.) Connect a -20 dBm to 0 dBm from 9.30 - 9.50 GHz, signal to RF INPUT, J102 (Figure 2.1). 2.) Connect the L-BAND OUTPUT, RF1 OUT, J101 to the external equipment.
Page 9
FUSE DRAWER SPARE FUSE AC Fuse - 2 amp slow blow (Type T), 5 mm X 20 mm FUSE INPUT 100-240± 10%VAC TYPE T 2A GDC 47-63 Hz 250 VOLT 2A MAX FOR 100 - 240 V~ FIGURE 2.3 Fuse Location and Spare Fuse 2117-9395_Manual Page 9 09/12/19...
Page 10
Use Information A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack. B. Mechanical Loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution.