Troubleshooting/Maintenance
Condition
Over-
Temperature
Resetting
the inverter
Fusing
Your Tripp Lite inverter is fitted with fuses which should not have to
be replaced under normal operating conditions. Blown fuses usually
indicate a reversed polarity or short circuit within the device or
equipment.
If the fuses are blown on the PINV750, additional fuses are included
to swap these out.* If the replacement fuses continue to blow, contact
Tripp Lite Customer Support at 773.869.1234.
*PINV1000 contains internal fuses that are not user-serviceable. Contact
Tripp Lite Customer Support for assistance if fuses are blown.
18-06-149-93385F.indb 19
Explanation
The thermal resistor
exceeds 176° F (80° C).
19
Solution
Allow the inverter to cool.
Do not block the cooling
slots or airflow over and
through the inverter.
Reduce the load on the
inverter to the continuous
rated output.
To reset after shutdown
occurs, switch the
inverter's ON/OFF switch
to the OFF (O) position.
Check the source of the
problem and correct.
Switch the inverter's ON/
OFF switch to the ON (I)
position.