4.4
Technical data
Model
Type
Heat output (Hi)
(1)
Fuel
Operation
Use
Ambient temperature
Combustion air temperature
Electrical supply
Fan motor
Ignition transformer
Capacitor
Absorbed electrical power
Protection level
Weight
Noise levels
Sound pressure
(2)
Sound power
Reference conditions: Room temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
(1)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output. The sound
(2)
power is measured with the "Free Field" method, as per EN 15036, and according to an "Accuracy: Category 3" measuring accuracy, as set out in
EN ISO 3746.
For gas family 3 (LPG) ask for separate kit.
WARNING
4.5
Maximum dimensions
The maximum dimensions of the flange and burner are given in
Fig. 1.
Flange
Ø 170
130
D5066
20147064
Technical description of the burner
kW
min - max
kcal/h
Family 2
°C
°C max
rpm - rad/s
V - Hz
W
A
F
kW
kg
dB(A)
NCV 8 12 kWh/m
Pressure: min. 16 mbar – max. 200 mbar
Boilers: water and diathermic oil
2800 - 294
230 - 50
90
0.75
Primary 230V – Secondary 18 kV / 11 mA
Burner
272
28
8
GB
RIELLO 40 FS5
566 M
23 58
20,000 50,000
3
– 7,000 10,340 kcal/m
Intermittent (FS1)
0 - 50
60
1/230V / 50-60Hz
3380
230 - 60
90
0.8
2
0.15
IP40
10
59.4
70.8
100
48
3
Tab. C
295
Fig. 1