Operation; Maintenance - Schneider Airsystems CPM 310-10-20 W Original Operating Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
direction. The screw it open by 1/2 to 1
turn (Figure 3a).
2. During air extraction, oil deposits in the
form of droplets can be seen at the upper
sight glass. Dosing: 1 droplet oil at 300
– 600 l/min air consumption. Readjust If
necessary and check regularly.

2.5 Operation

Do not overload the compressor: do not
exceed the max. number of switching cy-
cles and the ratio of operating time to
standstill!
2.5.1
Insert
Switch on the compressor at the ON/OFF
switch (item 10). The compressor starts up
and switches off automatically at maximum
pressure.
2.5.2
Adjusting the working pressure

2.6 Maintenance

Interval / No later than Tasks
-- / As needed
-- / after each use
daily / commissioning
Once after 10 h / --
-- / Weekly
50 h / After 6 months
500 h / after 1 year
1,000 h / after 2 years
2,500 h / After 5 years
2.6.1
Before each maintenance task
1. Swtich on the compressor at the ON/OFF
switch (item 10). Disconnect the power
supply.
2. Depressurise the compressor: using the
blow gun, blow out all pressure from the
vessel.
Only drain oil if the unit has been suffi-
ciently cooled.
1. Pull up the adjustment button on the (fil-
2. Rotate clockwise = pressure is in-
3. Read the set working pressure on the
4. Press the adjustment button down to
2.5.3
1. Switch off the compressor.
2. Disconnect the power supply.
3. Disconnect plug nipple of air hose from
4. Clean compressor (Chap. 2.6.2), depres-
Clean compressor
Clean filter insert (FDM)
Drain condensate from pressure vessel
Drain condensate from FDM
Check the oil level, add oil if necessary.
Check screw connections
Check intake filter
Check V-belt tension (where applicable)
Clean intake filter
Change oil (1st oil change mineral or synthetic oil) 2.6.7
Change oil (with mineral oil)
Change intake filter
Change check valve and insert
Check screw connections
Change oil (with synthetic oil)
Change V-belts (where applicable)
Change safety valve
2.6.2
• Clean the cooling fins on the cylinder, cyl-
• Clean the fan impeller cover on the motor.
2.6.3
1. Depressurise vessel of FDM.
2. Hold a suitable vessel under the conden-
ter) pressure reducer (Figure 4a).
creased. Rotate anticlockwise = pressure
is reduced.
pressure gauge (item 13).
lock it in place.
After use
(safety) quick-action coupling (Fig. 3a) .
surise it (Chap. 2.6.1), transport to stor-
age location (Chap. 2.4.1).
Cleaning the compressor
inder head and aftercooler using com-
pressed air.
Clean FDM insert
sate drain. Drain condensate.
GB
UNM / CPM
See chap.
2.6.2
2.6.3
2.6.5
2.6.4
2.6.6
2.6.8
2.6.9
2.6.10
2.6.9
2.6.7
2.6.9
2.6.11
2.6.8
2.6.7
2.6.10
2.6.12
II/9

Advertisement

Table of Contents
loading

This manual is also suitable for:

A 213 000

Table of Contents