1.
Inspection
The following items are inside the box:
User's manual
UPS
Remove Power UPS from its package and
inspect it for damage that may have occurred
during shipping. If any damage is discovered,
re-pack the unit and return it to the place of
purchase.
2.
Place the UPS
Install this UPS in a
protected area that
is free of excessive
dust and provide
7.8-inch (20-cm)
clearance on sides for adequate airflow
around the unit.
Avoid direct sunlight
Avoid excessive heat
Avoid excessive humidity or liquids
Avoid excessive dust
3.
Connect UPS to Utility
Use the power cord that came with your UPS
to connect the UPS directly to the wall outlet.
Power Switch
Press and release the button to supply power to the Battery Power
Supplied Outlets. Press and release the button again to switch off
power to the Battery Power Supplied Outlets.
USER'S MANUAL
Battery Charging:
The UPS battery charges whenever the UPS
is connected to utility power and typically
requires less than eight hours to charge fully.
Operating runtime is reduced until the battery
is fully charged.
4.
Connect Equipment to UPS
Connect the equipment to either, Battery
Power Supplied or Surge-protected outlets.
Battery Power Supplied Outlets :
Connect computer, monitor, and external
drive to the "Battery Power Supplied" outlets.
These outlets provide battery backup, EMI
filtering, line conditioning, and surge
protection. Battery power is automatically
provided in case of power failure. Ensure
Power Switch is kept in the "ON" position,
otherwise, the UPS will be disabled and your
equipment will not be protected during a
power failure.
UPS INDICATORS & CONTROLS
Power Switch
UPS Status Indicator
AC mode: green lighting
Battery mode: yellow flashing
UPS fault: red lighting
CAUTION: DO NOT connect a printer or any
motorized products to any Battery Power
Supplied Outlet.
5.
Turn On/Off
To turn on the UPS unit, press the power
switch lightly. To turn off the UPS unit,
press the power switch again.
6.
Cold Start Function
When the UPS is off and there is no power
utility, it's still possible to cold start the UPS
unit to power the loads.
UPS Status Indicator
AC Mode Indicator:
This green LED is lit when the UPS transfers utility power to both
Battery Power Supplied Outlets and Full Time Surge Protection
Outlets.
Battery Mode Indicator
This yellow LED flashes when the utility power is outside acceptable
limits and the battery supplies power only through the Battery Power
Supplied Outlets.
Battery Mode: sounding every 10 seconds
Low Battery: sounding every seconds
UPS fault Indicator
This red LED is lit when the UPS occur fault.
Overload: sounding every 0.5 seconds
Fault: continuously sounding