Husky 41214 Instruction Manual page 18

1.5-gallon oil-free air compressor
Table of Contents

Advertisement

Regulator: Controls the air pressure shown on the outlet pressure gauge. Turn
knob clockwise to increase pressure and counterclockwise to decrease pressure.
Female Tire Chuck: Attaches to the hose end to be used to inflate tires.
Note: To ensure correct tire pressure use a tire pressure gauge. Blow Gun: Ideal
for blowing, cleaning, and inflating. Depress lever on to release the air. Attaches to
hose end.
Safety Nozzle: Prevents pressure build-up. Attaches to blow gun outlet.
Blow Gun Adapter: Attaches to the blow gun to allow the tapered Inflator, inflating
needle, or high flow inflator/deflator adapter body to be used.
Inflation needles: Used to inflate sport balls. Requires blow gun adapter.
Tapered Blow Gun Nozzle: Used to inflate toy infiatables/air mattresses. tapered
inflator attaches to blow gun Brass outlet and plastic tapered inflator requires the
blow gun adapter.
Rubber Tip Nozzle: Used to inflate toyinflatables/air mattresses. Attaches to blow
gun outlet.
Inflator/Deflator Adapter Body: Used with inflator/deflator nozzles it attaches
directly to the universal valve adapter to inflate or deflate air mattresses, small boats,
inflatable toys, and other inflatable items that use a large volume of low-pressure air.
Requires blow gun adapter.
Inflator/Deflator Nozzles: Used with the high flow inflator/deflator adapter body.
Thread Seal Tape: Used with inflator/deflator nozzles to prevent air from leaking out
of inflatables with very large air inlets.
Drain Valve (not shown): The drain valve is located at the base of the air tank and is
used to drain condensation at the end of each use.
Air Compressor Pump (not shown): Compresses air into the air tank. Working air is
not available until the compressor has raised the air tank pressure above that required
at the air outlet.
break-in instructions are not closely followed.This procedure is required before theair
compressor is put into service.
1. Make sure the Off/Auto-On switch is in the "Off" position.
2. Turn the regulator knob counterclockwise until it stops.
3. Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage
and Circuit Protection paragraph in the Installation section of this manual.)
4. Open the drain valve fully (counterclockwise) to permit air to escape and prevent
air pressure build up in the air tank during the break-in period.
5. Move the Off/Auto-On switch to "Auto-On" position. The compressor will start.
6. Run the compressor for 15 minutes. Make sure the drain valve is open and there
is minimal air pressure build-up in tank.
7. After 15 minutes, close the drain valve (clockwise). The air receiver will fill to
"cut-out" pressure and the motor will stop.
The compressor is now ready for use.
Risk of Unsafe Operation. Serious damage may result if the following
OPERATION
18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents