3 Before operation

Icon
Airflow rate = High
Airflow rate = Medium high
Airflow rate = Medium
Airflow rate = Medium low
Airflow rate = Low
Comfort operation is active
Auto vertical swing is active
ON timer is active
OFF timer is active
2.2.3

To operate the user interface

a
a
Signal receiver
1 Aim the signal transmitter at the signal receiver on the indoor
unit (maximum distance for communication is 7 m).
Result: When the indoor unit receives a signal from the user
interface, you will hear a sound:
Sound
Beep-beep
Beep
Long beep
3
Before operation
3.1

To fix the user interface to the wall

a
b
c
a
User interface
b
Screw
c
User interface holder
1 Choose a place where the signals reach the unit.
2 Attach the holder with screws to the wall or a similar location.
3 Hang the user interface on the user interface holder.
Operation manual
4
Description
Description
Operation starts.
Setting changes.
Operation stops.
3.2

To insert the batteries

The batteries will last for about 1 year.
1 Remove the back cover.
2 Insert both batteries at once.
3 Replace the back cover.
2
1
AAA.LR03
3.3

To turn on the power supply

1 Turn the circuit breaker on.
Result: The flap of the indoor unit will open and close to set the
reference position.
4

Operation

4.1

Operation range

Operation mode
(a)(b)
Cooling
▪ Outdoor temperature: –10~46°C
▪ Indoor temperature: 18~32°C
▪ Indoor humidity: ≤80%
(a)
Heating
▪ Outdoor temperature: –15~24°C
▪ Indoor temperature: 10~30°C
(a)
Drying
▪ Outdoor temperature: –10~46°C
▪ Indoor temperature: 18~32°C
▪ Indoor humidity: ≤80%
If operated outside the operation range:
(a)
A safety device might stop the operation of the system.
(b)
Condensation might occur on the indoor unit and drip.
4.2

When to use which feature

You can use the following table to determine which features to use:
Feature
Basic features
To start/stop the system and to set the
Operation modes and
temperature:
temperature
▪ Heat up or cool down a room.
▪ Blow air in a room without heating or
cooling.
▪ Decrease the humidity in a room.
▪ In Automatic mode, automatically
select an appropriate temperature
and operation mode.
To adjust the airflow direction (swing or
Airflow direction
fixed position).
To adjust the amount of air blown into
Airflow rate
the room.
To run more quietly.
3
Operation range
Tasks
FTXF20~71A2V1B
Daikin room air conditioner
3P511999-3 – 2017.11