Troubleshooting; Symptoms That Are Not System Malfunctions; Symptom: A Sound Like Water Flowing Is Heard - Daikin FTXF20A2V1B Operation Manual

Hide thumbs Also See for FTXF20A2V1B:
Table of Contents

Advertisement

7 Troubleshooting

INFORMATION
It is recommended to have periodical maintenance
performed by a specialist. For specialist maintenance,
contact your dealer. Maintenance costs shall be borne by
the customer.
In certain operating conditions the inside of the unit may
get dirty after several seasons of use. This results in poor
performance.
7
Troubleshooting
If one of the following malfunctions occur, take the measures shown
below and contact your dealer.
WARNING
Stop operation and shut off the power if anything
unusual occurs (burning smells etc.).
Leaving the unit running under such circumstances may
cause breakage, electric shock or fire. Contact your dealer.
The system MUST be repaired by a qualified service person:
Malfunction
If a safety device such as a fuse, a
breaker or an earth leakage breaker
frequently actuates or the ON/OFF
switch does NOT properly work.
If water leaks from the unit.
The operation switch does NOT work
well.
If the user interface display indicates the
unit number, the operation lamp flashes
and the malfunction code appears.
If the system does NOT properly operate except for the above
mentioned cases and none of the above mentioned malfunctions is
evident, investigate the system according to the following
procedures.
Malfunction
If the system does
▪ Check if there is no power failure. Wait
NOT operate at all.
until power is restored. If a power failure
occurs during operation, the system
automatically restarts immediately after
power is restored.
▪ Check if no fuse has blown or breaker is
activated. Change the fuse or reset the
breaker if necessary.
▪ Check the batteries of the user interface.
The system suddenly
▪ Check if the air inlet or outlet of the
stops operating.
outdoor or indoor unit is NOT blocked by
obstacles. Remove any obstacles and
make sure the air can flow freely.
▪ The air conditioner may stop operating
after sudden large voltage fluctuations to
protect the system. It automatically
resumes operation after about 3 minutes.
Operation manual
10
Measure
Turn OFF the main power
switch.
Stop the operation.
Turn OFF the power
supply.
Notify your installer and
report the malfunction
code.
Measure
Malfunction
The system operates,
▪ Check the airflow rate setting. Refer to
but cooling or heating
"4.3.2 Airflow rate" on
is insufficient.
▪ Check the temperature setting. Refer to
"4.3.1  To start/stop operation and to set
the temperature" on
▪ Check if the airflow direction setting is
appropriate. Refer to
direction" on
▪ Check if the air inlet or outlet of outdoor
or indoor unit is NOT blocked by
obstacles. Remove any obstacles and
make sure the air can flow freely.
The system operates
▪ The air conditioner may be warming up
but cooling or heating
for heat operation. Wait for about 1 to 4
is insufficient (air is
minutes.
NOT blown from the
▪ The unit may be in defrost operation.
unit).
The system operates,
▪ Check if the air filters are clogged. Clean
but cooling or heating
the air filters. See
is insufficient (air is
service" on
blown from the unit).
▪ Check for open doors or windows. Close
doors and windows to prevent wind from
coming in.
▪ Check if the unit operates in Econo
operation.
operation" on
▪ Check if there is any furniture directly
under or next to the indoor unit. Move the
furniture.
An abnormal function
The air conditioner may malfunction
happens during
because of lightning or radio waves. Turn
operation.
the breaker OFF and back ON.
The unit does NOT
▪ Check the batteries of the user interface.
receive signals from
▪ Check if the transmitter is NOT exposed
the user interface.
to direct sunlight.
▪ Check if there are any electronic starter
type fluorescent lamps in the room.
Contact your dealer.
The user interface
▪ Replace
display is blank.
interface.
An error code is
Consult your local dealer. Refer to
displayed on the user
"7.2 Solving problems based on error
interface.
codes" on page 11
error codes.
Other electric
If the user interface signals operate other
appliances start to
electric appliances, move the other
operate.
appliances away, and contact your dealer.
If after checking all above items, it is impossible to fix the problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).
7.1
Symptoms that are NOT system
malfunctions
The following symptoms are NOT system malfunctions:
7.1.1
Symptom: A sound like water flowing is
heard
▪ This sound is caused by the refrigerant flowing in the unit.
▪ This sound may be generated when water is flowing away from
the unit during cooling or drying operation.
Measure
page 5.
page 5..
"4.3.3  Airflow
page 6.
"6  Maintenance and
page 8.
Refer
to
"4.3.6  Econo
page 7.
the
batteries
of
the
user
for a detailed list of
FTXF20~71A2V1B
Daikin room air conditioner
3P511999-3 – 2017.11

Advertisement

Table of Contents
loading

Table of Contents