No Ice or Low Ice Production (cont)
5.
Check ejector position (cont)
D.
Ejector at 6:00 position
1.
Contamination (motor doesn't oscillate)
2.
Hollow cubes
3.
Insufficient water to ice maker (small cubes)
E.
Ejector at 7:30 position
1.
Contamination (motor doesn't oscillate)
2.
Bail arm stuck in ice or obstructed
3.
Pac-Man cubes (cubes not formed properly)
F.
Ejector at 9:00 position
1.
Contamination
2.
Cube frozen fo fill cup or mold
II.
Overproduction of Ice
1.
Bail shut-off arm not in actuator
2.
Misformed bail shut-off arm
3.
Shut-off lever broken or bypassing vertical cam
4.
Broken module actuator
III.
Hollow Ice Cubes
1.
Water fill volume too low
2.
Improper freezer air flow
3.
Thermostat out of calibration
IV.
Flooding; Ice Slabs in Bucket or Freezer
1.
Thermostat out of calibration
2.
Jammed cube stalls unit in water-fill cycle
3.
Leaky water valve
4.
Fill volume of water excessive
5.
Motor stalled in fill cycle (ejectors in 12:00 position)
6.
Contaminated module
7.
Refrigerator or ice maker not level
8.
Excessive water pressure
9.
Module shut-off switch and contacts shorted & burned
10.
Broken locking tab on vertical cam (stalled in fill cycle)
11.
Fill tube not properly located in fill cup
12.
Fill cup water opening flashed over or plugged
13.
Cubes fall over back of ice maker, melting into freezer
16022675
!
WARNING
1.
Adjust or repair freezer
1.
Replace ice maker
2.
Refer to Section III, "Hollow Cubes"
3.
Refer to Section III, "Hollow Cubes"
1.
Replace ice maker
2.
Remove obstruction or replace ice maker
3.
Un-jam unit; check fill-cup and fill-tube assembly
1.
Replace ice maker
2.
Un-jam unit; install new fill cup or new ice maker
1.
Replace bail shut-off arm in actuator; watch for
loose fit
2.
Replace bail shut-off arm
3.
Replace ice maker
4.
Replace ice maker
1.
Adjust screw on module; clear water path or
change water valve
2.
Redirect air flow away from ice-maker thermostat
3.
Apply fresh Alumilastic; replace ice maker
1.
Apply fresh Alumilastic; replace ice maker
2.
Remove cube; find cause of jamming
3.
Replace water valve
4.
Adjust screw on module; change water valve
5.
Replace ice maker
6.
Replace ice maker
7.
Level as necessary
8.
Lower pressure to 20-120 psi (1.4-8.2 bar)
9.
Replace ice maker
10.
Replace ice maker
11.
Reposition fill tube
12.
Install new fill cup
13.
Install new fill cup