Viking DMOR205SS Service Manual page 35

Hide thumbs Also See for DMOR205SS:
Table of Contents

Advertisement

Pin No.
Signal
I/O
18
P50
OUT
19
P47
OUT
20
P46
OUT
21
P45
OUT
22
P44
OUT
23
P43
OUT
24
P42
IN
25
INT1
IN
26
P40
IN
27
RST
IN
28
P71
OUT
29
P70
OUT
30
XIN
IN
Convection motor driving signal.
To turn on and off shut-off relay(RY7). "L" level during
CONVECTION; "H" level otherwise.
Hood lamp driving signal.
To turn on and off relay(RY8). "L" level: During Hood
lamp ON. "H" level: During Hood lamp OFF.
Hood motor driving signal.
To turn on and off relay(RY9). "L" level: During Hood
motor ON. "H" level: During Hood motor OFF.
Hood motor high / low driving signal.
To turn on and off relay(RY10). "L" level: During Hood
motor high. "H" level: During Hood motor low.
Timing signal output terminal for temperature measurement(OVEN).
"L" level (GND): Thermistor OPEN timing.
"H" level (-5V): Temperature measuring timing. (Convection cooking)
Signal to sound buzzer.
A: key touch sound.
B: Completion sound.
C: When the temperature of the oven cavity reaches
the preset temperature in the preheating mode, or
when the preheating hold time (30 minutes) is elapsed.
Input signal which communicates the damper open/close information to LSI.
Damper opened; "L" level signal(0V:GND).
Damper closed; "H" level signal(-5V).
Signal to synchronize LSI with commercial power source freqency.
This is the basic timing for all real time processing of LSI.
Connected to VC.
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied. Temporarily set
to "L" level the moment power is applied, at this time the LSI is reset. Thereafter set at
"H" level.
Magnetron high-voltage circuit driving signal.
To turn on and off the cook
relay(RY2). In P-HI operation, the
signals holds "L" level during micro-
wave cooking and "H" level while
not cooking. In other cooking modes
(P-90,P-80,P-70,P-60,P-50,P-40,P-
30,P-20,P-10,P-0) the signal turns
to "H" level and "L" level in repetition
according to the power level.
Heating element driving signal.
To turn on and off shut-off relay(RY3). "L" level during convection cooking; "H" level
otherwise. During convection cooking, the signal becomes
"H" level when the temperature of the oven cavity exceeds
the predetermined temperature.
Internal clock oscillation frequency setting input.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit with
respect to XOUT terminal.
33
Description
A
B
1 sec
C
VARI-MODE
P-HI (100% power)
P-90 (approx. 90% power)
P-80 (approx. 80% power)
P-70 (approx. 70% power)
P-60 (approx. 60% power)
P-50 (approx. 50% power)
P-40 (approx. 40% power)
P-30 (approx. 30% power)
P-20 (approx. 20% power)
P-10 (approx. 10% power)
P-0 (0% power)
VMOR205SS
DMOR205SS
H.
GND
During
OFF
cooking
(Convection)
ON
L
H : GND
OFF
L
ON
H : GND
OFF
ON
L
H : GND
OFF
ON
L
0.1 sec
2 sec
1 sec
H: GND
L
H : GND
L (-5V)
16.7 msec
ON TIME
OFF TIME
32 sec.
0 sec.
30 sec.
2 sec.
26 sec.
6 sec.
24 sec.
8 sec.
22 sec.
10 sec.
18 sec.
14 sec.
16 sec.
16 sec.
12 sec.
20 sec.
8 sec.
24 sec.
6 sec.
26 sec.
0 sec.
32 sec.
H.
GND
During
OFF
cooking
(Convection)
ON
L

Advertisement