Toshiba RAS-05J2KVG-EE Service Manual page 26

Split type
Hide thumbs Also See for RAS-05J2KVG-EE:
Table of Contents

Advertisement

RAS-13J2KVG-EE / RAS-13J2AVG-EE
P
Pressure measurement
Gauge attaching port
Vacuum pump connecting port
Deoxidized copper pipe
Outer dia. : 9.52mm
Thickness : 0.8mm
4-way valve
TS
Temp. measurement
INDOOR UNIT
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Muffler
Muffler
TD
Compressor
KSK89D53UEZ
Outdoor heat
exchanger
T2
Propeller fan
OUTDOOR UNIT
- 26 -
FILE NO. SVM-19004
Temp. measurement
T1
TC
TA
Strainer
Pulse Modulating
valve at liquid side
Strainer
TO
TE
13k Refrigerant amount : 0.46kg
NOTE :
Max.
: 15m
Min.
: 2m
Chargeless : 15m
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents