Sanyo PLC-XW55A Service Manual page 38

Chassis: kr6-xw55a00, kp6-xw50a00
Hide thumbs Also See for PLC-XW55A:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
3 CB - OFFSET AREA V START
4 CR - OFFSET AREA H START
5 CR - OFFSET AREA V START
6 Y - GAIN AREA H START
7 Y - GAIN AREA V START
8 CB - GAIN AREA H START
9 CB - GAIN AREA V START
10 CR - GAIN AREA H START
11 CR - GAIN AREA V START
12 Image AREA H WIDTH
13 Image AREA V HIGHT
14 Y - OFFSET TARTGET
15 CB OFFSET TARGET
16 CR OFFSET TARGET
17 Y - GAIN TARGET
18 CB - GAIN TARGET
19 CR - GAIN TARGET
20 OFFSET torelance
21 GAIN torelance
Group 280 AutoPC Adjsut
0 AutoPCAdjustEnable
1 Frequency Step
2 Frequency Threshold
3 Fine Phase
4 BLKDET
5 PHASEMSK
Group 290 PanelType * Panel Type Check
0 GammaL/R-View
1 GammaL/R-Change
Group 500 Composite (NTSC) Composite / S-Video
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 501 Composite (PAL) Composite / S-Video
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 502 Composite (SECAM) Composite / S-Video
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 510 SCART(480i)
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 511 SCART (575i)
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group 520 YCbCr (480i)
0 Total Dots
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Function
CB - Offset Acquiring Area V-Start Position
CR - Offset Acquiring Area H-Start Position
CR - Offset Acquiring Area V-Start Position
Y
YCBCR Level Acquiring Area
YCBCR Level Acquiring Area Height
Torelance of OFFSET Adj.
Torelance of GAIN Adj.
Auto-PC Adj Operation Enable if Un-
supported Signal Input
Frequency Steps of TotalDot
Total Dot Freqency Threshold
Do Phase Adj after Total Dot Adj.
Black Level Detection Area
Phase Detection Filter
Current Setting Check
Setting of Gamma
Initial
500
900
500
50
500
800
500
700
500
8
13
4
128
128
217
237
237
1
1
0
1
5
1
1
0
0
10
668
32
22
450
664
32
22
534
652
28
10
550
666
142
52
448
648
170
68
526
890
696
150
48
458
-38-
Range
Note
0 - 1000
If not used: use Y's value
0 - 1000
If not used: use Y's value
0 - 1000
If not used: use Y's value
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
1 - 255
1 - 255
0 - 1
0: Enable, 1: Disable
0-3
0 - 10
0 [] <--- -----> 10[Not matched]
0 - 1
0: Executes Fine Phase, 1: Not Execute
0 - 3
0: Effective All Bit,
0 - 3
1: Disable Lower 1 bit
2: Disable Lower 2 bit, 3: Disable Lower 3 bit
0: Gamma for L-Turn
0-20
20: Gamma for R-Turn * Read only
Sets L-Turn Gamma if the Value is set to 0.
0-20
Sets R-Turn Gamma if the Value is set to 20.
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095
0 ~ 4095

Hide quick links: