Optical Parts Disassembly
, Locations and Directions
When mounting or assembling the optical parts in the opti-
cal unit, the parts must be mounted in the specified loca-
tion and direction as shown in figure below.
1
2
3
The printed part no.
comes to this side.
4
The printed part no.
comes to this side.
5
6
7
8
No.
Parts Name
1
Integrator lens (OUT)

Prism beam splitter (PBS)
3
Condenser lens (OUT)
4
Dichroic mirror (B)
5
Dichroic mirror (G)
6
Condenser lens (G)
7
Relay Lens (IN)
8
Mirror (R)
9
Condenser lens (R)
10
Condenser lens (B)
11
Mirror (B)
direction of Integrator lens-out
PLc-XW55A
Rugged surface is facing to the PBS side.
PLc-XW50A
Rugged surface is facing to the lamp side.