Sanyo PLC-XW55A Service Manual page 37

Chassis: kr6-xw55a00, kp6-xw50a00
Hide thumbs Also See for PLC-XW55A:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
91 FAN_2_AUTO_ADJ
92 FACTORY_STD_FAN_VOL_MIN
93 FACTORY_STD_FAN_VOL_MAX
94 FAN1_ADJUST_VOLT_MIN
95 FAN1_ADJUST_VOLT_MAX
96 FAN2_ADJUST_VOLT_MIN
97 FAN2_ADJUST_VOLT_MAX
TEMP_ERROR_DETECT_MAX_
98
TIMES
99 FAN_1_MIN_VOL_LAMP_DIFF
100 FAN_2_MIN_VOL_LAMP_DIFF
101 LAMP_VOL_BORDER_LINE
102 LAMP_VOL
103 Dimmer Voltage Change Cycle
104 Dimmer Average Check Period
105 Dimmer Voltage Change rate
106 Dimmer Average
107 Last Voltage Difference
108 Voltate Difference Goal
109 Temp Diff Normal
110 Temp Diff Eco
111 Temp Diff Normal High
112 Temp Diff Eco High
113 Temp Diff Normal Ceil
114 Temp Diff Eco Ceil
115 Temp Up Time Normal
116 Temp Up Time Eco
117 Temp Up Time Normal High
118 Temp Up Time Eco High
119 Temp Up Time Normal Ceil
120 Temp Up Time Eco Ceil
121 Standby Cooling Check Cycle
122 Standby Cooling Start Threshold
123 SAfter Shutdown Cooling
124 OnStart Cooling Start Threshold
Group 260 Auto Calibration (Commn) * Auto Calibration
0 Execute Calibration
1 Loop Count
2 Auto Status
3 AutoWait
4 CHECK -Tolelance
Group 261 Auto Calibration (RGB)
0 OFFSET AREA H START
1 OFFSET AREA V START
2 GAIN AREA H START
3 GAIN AREA V START
4 Image AREA H WIDTH
5 Image AREA V HIGHT
6 OFFSET target
7 OFFSET torelance
8 GAIN target
9 GAIN torelance
Group 262 Auto Calibration (CVBS/SVIDEO)
0 Y Image Area Start X
1 Y Image Area Start Y
6 Image Area H Width
7 Image Area V Hight
8 Y Target Level
11 Gain Tolerance
12 Delta Gain
Group 264 Auto Calibration (YCbCr)
0 Y-OFFSET AREA H START
1 Y-OFFSET AREA V START
2 CB - OFFSET AREA H START
Function
0: OFF (Manual), 1: ON (Auto)
For Factory Adjustment Ref FAN Voltage Min
(Initial 5V)
For Factory Adjustment Ref FAN Voltage Min
(Initial 13.5V)
For Factory Adjustment FAN1 Drive Voltage
Min
For Factory Adjustment FAN1 Drive Voltage
Max
For Factory Adjustment FAN2 Drive Voltage
Min
For Factory Adjustment FAN2 Drive Voltage
Max
Temp Failure when The Sensor detects an
error X times sequentially
Up Volume of FAN1 Control Min
(Unit Vx10)
Up Volume of FAN2 Control Min
(Unit Vx10)
Threshold Lamp Volatge of the above items
(Unit Vx10)
Current Lamp Voltage (V)
(Effective 30 sec. after turn on)
Voltage Change Cycle at Dimmer (Unit: sec)
Measuring Time at Dimmer (Unit: sec)
Voltage Change Volume at Dimmer (Unit: 0.1V)
Avarage Value of Dimmer
Last Voltage defferential Value
Target Voltage Dif. Value at Dimmer (Unit: 10V)
Maximum Execution Times (OFFSET->GAIN)
Result of Auto-Calibration (Last Memory)
Wait Value for each setting
Torelance of OFFSET
Black Level Acquiring Area H-Start Position
Black Level Acquiring Area V-Start Position
White Level Acquiring Area H-Start Position
White Level Acquiring Area V-Start Position
Black/White Level Acquiring Area
Black/White Level Acquiring Area Height
Target Value of Black Level Adj.
Torelance of Black Level Adj.
Target Value of White Level Adj.
Torelance of White Level Adj.
Y Acquiring Area H-Start Position
Y Acquiring Area V-Start Position
Image Level Acquiring Area
Image Level Acquiring Area Height
Target Value of Y Level Adj.
Torelance of Level Adj.
Deviation Width of Gain Value
Y - Offset Acquiring Area H-Start Position
Y - Offset Acquiring Area V-Start Position
CB - Offset Acquiring Area H-Start Position
Initial
-
50 / 50
135 / 135
40 / 40
210 / 210
10 / 10
210 / 210
5 / 5
0 / 0
0 / 0
70 / 70
- / -
3 / 3
10 / 10
1 / 1
- / -
- / -
- / -
0 / 0
0 / 0
0 / 0
0 / 0
0 / 0
0 / 0
0 / 0
0 / 0
0 / 0
0 / 0
0 / 0
0 / 0
5 / 5
54 / 54
1 / 1
38 / 38
0
10
0
1
2
975
500
25
500
13
9
3
1
238
1
20
500
13
20
217
1
9
900
500
900
-37-
Range
Note
0-1
0-255
0-255
0-255
* Fan Voltage adjustment
0-255
* Fan Voltage adjustment
0-255
* Fan Voltage adjustment
0-255
* Fan Voltage adjustment
1-9
0-20
0-20
30-90
0-255
* Read only
1-?
1-?
1-?
-
* Read only
-
* Read only
-
* Read only
0: No, 1: Yes
0-100
Executes Auto-Calibration when changiing
0 - 1
the Value (PC White 100%)
1 - 30
0 / 1 / 9
0: OK, 1: Adjusting,2: Error * ReadOnly
1 - 20
1 - 255
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 127
1 - 127
0 - 255
1 - 255
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 255
0 - 255
0 - 255
0 - 1000
0 - 1000
0 - 1000
If not used: use Y's value

Hide quick links: