Electrical Adjustments
Group/
Item Name
Item
6 DIMMER_CTRL_LEVEL7
7 DIMMER_CTRL_LEVEL8
8 DIMMER_CTRL_LEVEL9
9 DIMMER_CTRL_LEVEL10
10 DIMMER_CTRL_LEVEL11
11 DIMMER_CTRL_LEVEL12
12 DIMMER_CTRL_LEVEL13
13 DIMMER_CTRL_LEVEL14
14 DIMMER_CTRL_LEVEL15
15 DIMMER_AVERAGE_POINT
16 DIMMER_AVERAGE_DATA
17 DIMMER_LEVEL_AUTO
18 DIMMER_LEVEL_NORMAL
19 DIMMER_LEVEL_ECO
20 Lamp check enable
21 VOLTAGE_LEVEL
Group 250 FAN Cntorol
0 FAN_TEMP_A_WARNING
1 FAN_TEMP_B_WARNING
2 FAN_TEMP_C_WARNING
3 FAN_TEMP_B A_WARNING
4 FAN_TEMP_C A_WARNING
5 FAN__SPEED_MONI
6 FAN__SPEED_MONI
7 FAN_TEMP_A_MONI
8 FAN_TEMP_B_MONI
9 FAN_TEMP_C_MONI
10 Lamp Mode
11 Fan Ctrl Mode
12 Fan Switch
13 Hi-Land Switch
14 Safety Switch
15 Fan1 Manual Voltage
16 Fan2 Manual Voltage
TEMP_UPWARNING_TIME_A
17
(OUTSIDE)
TEMP_UPWARNING_TIME_B
18
(PANEL)
TEMP_UPWARNING_TIME_C
19
(LAMP)
20 TEMP_UPWARNING_TIME_B-A
21 TEMP_UPWARNING_TIME_C-A
UPWARNING_TEMP_A
(OUT-
22
SIDE)
23 UPWARNING_TEMP_B (PANEL)
24 UPWARNING_TEMP_C (LAMP)
25 UPWARNING_TEMP_B-A
26 UPWARNING_TEMP_C-A
27 FAN_1_START_SPEED
28 FAN_2_START_SPEED
31 FAN_1_COOLING_SPEED
32 FAN_2_COOLING_SPEED
33 FAN_1_TEMPERROR_SPEED
Function
Luminance Level 7 Data for Dimmer: Dim
Level 7 at the less than the Value
Luminance Level 8 Data for Dimmer: Dim
Level 8 at the less than the Value
Luminance Level 9 Data for Dimmer: Dim
Level 9 at the less than the Value
Luminance Level 10 Data for Dimmer: Dim
Level 10 at the less than the Value
Luminance Level 11 Data for Dimmer: Dim
Level 11 at the less than the Value
Luminance Level 12 Data for Dimmer: Dim
Level 12 at the less than the Value
Luminance Level 13 Data for Dimmer: Dim
Level 13 at the less than the Value
Luminance Level 14 Data for Dimmer: Dim
Level 14 at the less than the Value
Luminance Level 15 Data for Dimmer: Dim
Level 15 at the less than the Value
Luminance Data Avarage Point for Mimmer
Luminance Data Avarage Value for Dimmer
Current Dimmer Leverl
Normal Dimmer Level
Eco Dimmer Level
Lamp Voltage
Temperature A to judge the Temp. Failure
Outside
Temperature B to judge the Temp. Failure
Panel
Temperature C to judge the Temp. Failure
Lamp
Temperature B-A to judge the Temp. Failure
Filter Cloggled
Temperature C-A to judge the Temp. Failure
Filter Cloggled
Fan Speed Monitor
Fan Speed Monitor
Temp. Sensor Monitor
Temp. Sensor Monitor
Temp. Sensor Monitor
Normal/Auto/Eco
Normal/Ceiling Switch
Auto/Max/Min/Manual Switch
Hi-Land Switch
FAN Control
Manual Adjustment Mode at FAN_CON-
TROL_SW=3
Manual Adjustment Mode at FAN_CON-
TROL_SW=3
Raise Temp Failure Value for X minutes after
Power ON
Raise Temp Failure Value for X minutes after
Power ON
Raise Temp Failure Value for X minutes after
Power ON
Raise Temp Failure Value for X minutes after
Power ON
Raise Temp Failure Value for X minutes after
Power ON
Raise Temp Failure Value for a certain
minutes after Power ON
Raise Temp Failure Value for a certain
minutes after Power ON
Raise Temp Failure Value for a certain
minutes after Power ON
Raise Temp Failure Value for a certain
minutes after Power ON
Raise Temp Failure Value for a certain
minutes after Power ON
FAN1 Start Voltage 8V Unit VX10
FAN2 Start Voltage 8V Unit VX10
FAN1 Voltage at Power OFF (Fan Mode L1)
FAN2 Voltage at Power OFF (Fan Mode L1)
FAN1 Voltage at Temp. Failure
Initial
61
70
79
88
96
105
255
255
255
4
-
-
12
0
1
XW55A / XW50A
Normal-
Ceiling-
Normal
Ceiling
HiLand
HiLand
39 / 43
40 / 44
34 / 33
34 / 34
63 / 66
64 / 67
52 / 52
56 / 58
72 / 75
73 / 76
64 / 64
67 / 66
100/100 100/100 100/100
100/100
100/100 100/100 100/100
100/100
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1 / 1
0 / 0
0 / 0
0 / 0
0 / 0
130 / 130
130 / 130
3 / 3
3 / 3
3 / 3
3 / 3
3 / 3
5 / 5
5 / 5
5 / 5
5 / 5
5 / 5
55 / 45
65 / 65
100 / 100
100 / 100
130 / 130
-35-
Range
Note
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 16
-
* Read only
-
* Read only
0 - 15
0 - 15
0: Lamp Failure Detection OFF (White 50%
Back), 1 : ON (Blue 100% Back)
Unit: 8bit(Raw Data) * Read only
30-100
(Memorized)
30-100
(Memorized)
30-100
(Memorized)
(Memorized)
0-100
(Memorized)
0-100
-
* Read only
* Read only
* Read only
* Read only
* Read only
0-2
0:Normal, 1: Auto, 2: Eco
0-1
0: Normal, 1: Ceiling
0-3
0: Auto 1: Max 2:Min 3: Manual
0: Normal Mode , 1: High-land Mode
0-5
2˜4: High-land Mode1 ˜ 3, 5: Fixed(13.5V)
0-4
* Test Purpose
0-255
0-255
0-5
0-5
0-5
0-5
0-5
?
?
?
?
?
0-255
0-255
0-255
0-255
0-255