AEG HG653430 User Manual page 15

Table of Contents

Advertisement

To replace the connection
cable use only H03V2V2-F
T90 or equivalent type.
Make sure that the cable
section is applicable to the
voltage load and the
working temperature. The
yellow/green earth wire (B)
must be approximately 2 cm
longer than the live and
neutral wire (A).
1. Connect the green and yellow (earth)
wire to the terminal which is marked
with the letter 'E', or the earth
symbol
, or coloured green and
yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the
letter 'N' or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the
letter 'L'. It must always be
connected to the network phase.
There must be no cut or stray strands
of wire present. The cord clamp must
be correctly attached to the outer
sheath.
8.8 Building In
min. 600 mm
min. 450 mm
min. 55 mm
30 mm
480 mm
A
B
min. 650 mm
560 mm
A) supplied seal
B) supplied brackets
CAUTION!
Install the appliance only on
a worktop with flat surface.
8.9 Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance
intervention is necessary.
Kitchen unit with door
A
60 mm
B
A) Removable panel
B) Space for connections
ENGLISH
15
A
B
30 mm
min 20 mm
(max 150 mm)

Advertisement

Table of Contents
loading