PVH58
Air Intake Adjustment
The PVH58 is shipped with the air intake adjustment fully closed. This will produce maximum draw at the fireplace.
Longer runs require more draw, while shorter runs require less.
If flame pattern is slow and lazy, and sooting is occurring, more draw is required.
If flame pattern is running too fast, less draw is required.
Flame pattern should appear similar to below:
-AIR INTAKE ADJUSTMENT-
If air intake adjustment is required, loosen screw at bottom of Power Vent as shown. Move adjuster slightly while having a
helper watch the flame pattern. Once the desired draw has been set, re-tighten adjuster screw.
Move adjuster while having a helper watch the flame
Loosen screw at bottom of Power Vent
pattern.
Once the desired draw has been set, re-tighten adjuster
Air Intake has been set.
screw.
77