Kingsman Marquis Atrium MCVP42NH Installation Instructions Manual

Hide thumbs Also See for Marquis Atrium MCVP42NH:
Table of Contents

Advertisement

Quick Links

All manuals and user guides at all-guides.com
Installation Instructions
Model Numbers:
MCVP42N, MCVP42NE, MCVP42LP, MCVP42LPE
ANSI Z21.50-2014 • CSA 2.22-2014
ZERO CLEARANCE VENTED GAS FIREPLACE
Model Numbers:
MCVP42NH, MCVP42NHE, MCVP42LPH, MCVP42LPHE
ANSI Z21.88-2014 • CSA 2.33-2014
ZERO CLEARANCE VENTED GAS FIREPLACE HEATER
Certified to:
Certified to:
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For Propane Horizontal installations the
venting must be an additional one foot
above the minimum vertical rise off the flue
This appliance may be installed in an
aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
before going horizontal.
ATRIUM
A Division of R-Co. Inc.
2340 Logan Ave.
Winnipeg, Manitoba Canada
R2R 2V3 Ph.: (204) 632-1962
Printed in Canada May 5, 2015
Part# 42MCVP-MAN14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Marquis Atrium MCVP42NH and is the answer not in the manual?

Questions and answers

Summary of Contents for Kingsman Marquis Atrium MCVP42NH

  • Page 1 All manuals and user guides at all-guides.com Installation Instructions Model Numbers: MCVP42N, MCVP42NE, MCVP42LP, MCVP42LPE Certified to: ANSI Z21.50-2014 • CSA 2.22-2014 ATRIUM ZERO CLEARANCE VENTED GAS FIREPLACE Model Numbers: MCVP42NH, MCVP42NHE, MCVP42LPH, MCVP42LPHE Certified to: ANSI Z21.88-2014 • CSA 2.33-2014 ZERO CLEARANCE VENTED GAS FIREPLACE HEATER This appliance may be installed in an aftermarket, permanently located,...
  • Page 2: Table Of Contents

    All manuals and user guides at all-guides.com Table of Contents INFORMATION Table of Contents…………………………………………………………………………………………………………... Glass Safety / Termination Cap Safety- All Units……………………………………………………………………………... Warnings, Installations, and Operations……………………………………………………………………………………….. Pre-installation Questions and Answers……………………………………………………………………………………….. Operating Instructions……………………………………………………………………………………………………………. Recommendations for Finishing of Clean View Installations…………………………………………………………..Mobile Home/Manufactured Housing Installation…………………………………………………………………………….. MCVP42 INSTALLATION Framing- Nailing Tab Guide……………………………………………………………………………………………………...
  • Page 3 All manuals and user guides at all-guides.com IPI SECTION IPI Electronic Ignition System……………………………………………………………………………………………... Remote Control Operation………………………………………………………………………………………………………. IPI Electronic Ignition Parts List – Standard System…………………………………………………………………………. Configuration 1: Basic Manual Hi / Lo and manual Off………………………………………………………………………. Configuration 2: Remote On / Off and manual Hi / Lo……………………………………………………………………….. Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls………………………………...
  • Page 4: Glass Safety / Termination Cap Safety- All Units

    All manuals and user guides at all-guides.com -Glass Safety- All Units IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.
  • Page 5: Warnings, Installations And Operations

    All manuals and user guides at all-guides.com Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the National Electrical Code;...
  • Page 6 All manuals and user guides at all-guides.com  Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source.  This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 7: Pre-Installation Questions And Answers

    All manuals and user guides at all-guides.com Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 8: Recommendations For Finishing Of Clean View Installations

    All manuals and user guides at all-guides.com Recommendations for Finishing of Clean View Installations When finishing the wall around the fireplace, it is critical that the wall covering be fastened properly. It is acceptable to pre-drill holes and use self-tapping screws which may be used to fasten a backer for tile, marble, etc. Screws being installed through non-combustible board should be self-tapping type with a maximum length of 2 inches.
  • Page 9: Mobile Home/Manufactured Housing Installation

    All manuals and user guides at all-guides.com Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 10: Framing- Nailing Tab Guide

    All manuals and user guides at all-guides.com MCVP42 Framing- Nailing Tab Guide [Qty] 4 Nailing Tabs are located on flue side of fireplace. These Nailing Tabs can be used in two ways: 1/2” Drywall Flush with Face of Fireplace – Framing Flush with Face of Fireplace -Fireplace to be covered with Non-Combustibles (e.g.
  • Page 11: Framing Your Gas Fireplace

    All manuals and user guides at all-guides.com MCVP42 Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electrical accesses are located on the unit. This will streamline the construction process. Furthermore, familiarize yourself with the venting and clearance requirements (see Venting section) for this appliance.
  • Page 12: Locating Your Appliance / Fireplace Dimensions

    All manuals and user guides at all-guides.com MCVP42 Locating Your Appliance See Mantel Leg Clearances Instruction for the proper placement of fireplace. PENINSULA ISLAND ALL UNITS MAY BE VENTED VERTICALLY MCVP42 Fireplace Dimensions...
  • Page 13: Framing Dimensions

    All manuals and user guides at all-guides.com MCVP42 Framing Dimensions These structures are not load bearing. Optional- floor cutout for gas line if Framed fireplace opening. coming up through floor. TOP VIEW Vent Framing (Vertical or Horizontal) Vertical Venting MUST maintain 1” clearance to combustibles. 9”...
  • Page 14: Facing Requirements

    All manuals and user guides at all-guides.com MCVP42 Facing Requirements Required Non-Combustible Areas If you are covering the face of the fireplace: NOTE: MATERIALS COVERING THE FACE OF THE FIREPLACE MUST BE NON-COMBUSTIBLE It is also recommended to attach Non-combustible facing to framing. Note: Do not drive excessively long screws into the face of the unit as internal parts may be damaged.
  • Page 15: Basic Finishing Mcvp42

    All manuals and user guides at all-guides.com Basic Finishing MCVP42 Step One: Frame Fireplace with nailing tabs oriented as Step Two: Use Drywall to finish face of wall. shown. NOTE: Drywall will be flush with fireplace face. Drywall Fireplace Frame Fireplace Frame Nailing Tab Step 3: A brick, tile, or other non-combustible border may be applied over fireplace face to conceal border.
  • Page 16: Mantel Clearances

    All manuals and user guides at all-guides.com MCVP42 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of mantels to consider: Combustible and Non-Combustible. A Combustible Mantel is one that consists of material(s) that may discolor, combust, or lose its integrity in the presence of heat.
  • Page 17: Clearance To Combustibles

    All manuals and user guides at all-guides.com MCVP42 Clearance to Combustibles Clearance to Combustibles MCVP42 24” Front and Sides 0” Back (from Stand-offs) 0” Floor* *Note: If appliance is installed directly on carpeting or other combustible material other than wood flooring, a metal or wood panel extending the full width and depth of the appliance must be used.
  • Page 18: Safety Screen Installation

    All manuals and user guides at all-guides.com MCVP42 Child Safety Screen Installation Contents of Kit: [3] Child Safety Screens- Ready to Install Assembly Instructions: Attach screen to fireplace as per instructions below. NOTE: Screens are symmetrical from top to bottom. ⚠...
  • Page 19: Mp42Pl Porcelain Liner Installation

    All manuals and user guides at all-guides.com MP42PL Porcelain Liner Installation ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Instructions: (NOTE: Porcelain Liners should be installed BEFORE Log Grates or Glass Tray.) Step One: Remove Main Burner (refer to Burner Removal section).
  • Page 20: Mp42Rl Brick Liner Installation

    All manuals and user guides at all-guides.com MP42RL -Brick Liner Installation- When using M42LG Log Grates NOT FOR USE WITH MP42GT. NOTE: Brick Liner must be installed BEFORE MP42RL Consists of: M42LG is installed. [1] – Back Liner NOTE: Either Baffle (Heater Rated Units) or Deflectors (Decorative Units) must be removed.
  • Page 21: Baffle Removal (Heater Rated Units) / Deflector Removal (Decorative Units)

    All manuals and user guides at all-guides.com ZCV42MCVP Baffle Removal (Heater Rated Units) To Remove Baffle: Remove [5] DT Screws holding Baffle in place. NOTE: Remove end screw last. See below. To Replace Baffle: Hook Mount Tab onto ledge at top of firebox. Replace end screw first.
  • Page 22: Mp42-Gt Installation / Removal

    All manuals and user guides at all-guides.com MP42-GT Installation / Removal 42MCVP Contents of Kit: 1 Glass Tray NOT FOR USE WITH MP42RL. Instructions: ⚠ To Install: Place Glass Tray into NOTE firebox as shown.  Pilot Area Must Not Be Covered, as delayed ignition can occur.
  • Page 23: M42-Lg Installation / Removal

    All manuals and user guides at all-guides.com M42-LG Installation / Removal 42MCVP Contents of Kit: 1. [2] Log Grates 2. [2] Large Bags 3/4” Lava Rock 3. [3] 350 Embers 4. [1] Vermiculite 5. [1] Insulation Wool 6. [1] Grate Plate 7.
  • Page 24: Mq42Log1 8 Piece Driftwood Log Set - For Use With Gt Glass Tray

    All manuals and user guides at all-guides.com MQ42LOG1 8 Piece Driftwood Log Set - For use with GT Glass Tray ⚠ PILOT WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in...
  • Page 25: Mq42Log1 8 Piece Driftwood Log Set - For Use With M42Lg Log Grate

    All manuals and user guides at all-guides.com MQ42LOG1 8 Piece Driftwood Log Set - For use with M42LG Log Grate Place 350 Embers from M42LG in PILOT Burner Tray Place Insulation Wool from M42LG in Burner Tray Place Lava Rock from M42LG on Grates and Firebox Bottom Place Vermiculite from...
  • Page 26: Mq42Log2 7 Piece Oak Log Set - For Use With Gt Glass Tray

    All manuals and user guides at all-guides.com MQ42LOG2 7 Piece Oak Log Set - For use with GT Glass Tray PILOT ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 27: Mq42Log2 7 Piece Oak Log Set - For Use With M42Lg Log Grate

    All manuals and user guides at all-guides.com MQ42LOG2 7 Piece Oak Log Set - For use with M42LG Log Grate PILOT Place 350 Embers from Place M42LG in Insulation Burner Tray Wool from M42LG in Burner Tray Place Lava Place Rock from Vermiculite M42LG on...
  • Page 28: M42Log3 6 Piece Driftwood Log Set - For Use With Gt Glass Tray

    All manuals and user guides at all-guides.com M42LOG3 6 Piece Driftwood Log Set - For use with GT Glass Tray PILOT ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in...
  • Page 29: M42Log4 8 Piece Oak Log Set - For Use With M42Lg Log Grate

    All manuals and user guides at all-guides.com M42LOG4 8 Piece Oak Log Set - For use with M42LG Log Grate PILOT Place 350 Place Insulation Embers from Wool from M42LG M42LG in in Burner Tray Burner Tray ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use...
  • Page 30: Uhs Box / Component Locations

    All manuals and user guides at all-guides.com MCVP42 51UHS Box Included with base model. The 51-UHS Box is designed for millivolt and IPI units for in-unit installation of the Remote Receiver, Fan Control Module, and the IPI Module. 51-UHS Box can be inserted & removed from beneath fireplace through access panel opening (Remove glass door first). NOTE: When using a remote control, the 51-UHS Box must be used.
  • Page 31: Ulk3 Universal Light Kit

    All manuals and user guides at all-guides.com ULK3 Universal Light Kit ( Optional Accent Lighting Kit) MCVP42 & MCVST42 Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. Contents of Kit: Inside Firebox ...
  • Page 32: Split Receptacle- Switch Control Outside Of Fireplace

    All manuals and user guides at all-guides.com Split Receptacle- Switch Control Outside of Fireplace If you wish to have a control switch outside of the fireplace for one side of the receptacle and you require a constant source of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures below.
  • Page 33: Rbcb1 -Cannonballs- Installation Instructions

    All manuals and user guides at all-guides.com RBCB1 -Cannonballs- Installation Instructions *Must be used with MST42GT/ MP42GT Glass Tray Assorted size and colors. Place randomly as desired inside fireplace. PILOT Can be used with MQ Glass, MQ Ember, and / or Lava Rock. Do not place Cannonballs directly on burner ports. If sooting occurs change position of or remove affected objects.
  • Page 34: Mq Dealer Accessories For Mcvst42 / Mcvp42 (Glass)

    All manuals and user guides at all-guides.com MQ Dealer Accessories for MCVST42 / MCVP42 The following Accessories are available through MQ Dealers only.  GLASS (MQG5W, MQG5C, MQG5A, MQG5B, MQG5ZG) ACCESSORY ITEM DESCRIPTION If you wish to use this media evenly spread the glass embers onto the false bottom and burner.
  • Page 35: Mqstone, Mqrock, Mqember

    All manuals and user guides at all-guides.com MQ STONE / MQ ROCK- Must be used with MST42GT/ MP42GT Glass Tray The following Accessories are available through MQ Dealers only. MQ STONE DECORATIVE STONE SET- Must be used with Glass Tray MST42GT/ MP42GT PILOT NOTE...
  • Page 36: Door Installation

    All manuals and user guides at all-guides.com ZCV39 / ZCV42 / MCVST42 / MCVP42 Door Installation To install Door: 1. Remove Access Cover below Glass Door. 30° 15° 2. Engage door in lower latches at an angle of between 15 and 30 degrees. 3.
  • Page 37: Door And Glass Information

    All manuals and user guides at all-guides.com Door and Glass Information MCVP42 Glass Cleaning It will be necessary to clean the glass periodically. During startup, condensation, which is normal, forms on the inside of the glass, and causes dust, lint etc. to cling to the glass surface. Also, initial paint curing can deposit a slight film on the glass.
  • Page 38: Gas Line Installation

    1/2 PSIG (3.5 KPa). NOTE: The gas line connection may be made of 1/2” rigid pipe or an Approved Kingsman Flex Connector, such as FP15GC.
  • Page 39: Millivolt System, Lighting, And Burner Control

    All manuals and user guides at all-guides.com Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING ...
  • Page 40: Troubleshooting The Gas Control System

    All manuals and user guides at all-guides.com Troubleshooting the Gas Control System WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Possible Causes Corrective Action...
  • Page 41: Burner System Maintenance

    All manuals and user guides at all-guides.com Burner System Maintenance- MCVST42 / MCVP42 It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 42: Conversion Kit Instructions - Part A

    All manuals and user guides at all-guides.com Gas Conversion Part A MCVP42 Models: MCVP42LP, MCVP42N, MCVP42LPE, MCVP42NE Description Pilot Orifice Burner Orifice Brass Nipple Air Shutter Hi/Lo Regulator Kit Number Brass (1000-255) 42MP-CKLP LP Conversion 1001-P167SI 1000-253 Fully Open 1001-P202SI -Millivolt- #30 (977.167) Closed...
  • Page 43: Gas Conversion Kit For Top Convertible Pilot Part B

    installationinstructions All manuals and user guides at all-guides.com gas conversion kit for top convertible pilot series 0190XYZ) Instructions for converting SIT 190 series pilot burner injector from NG to LPG and from LPG to NG only. This information should be considered as supplemental to the Appliance Manufacturer's Instructions. Warning! The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 44: Gas Conversion For Modulator - Part C

    All manuals and user guides at all-guides.com Gas Conversion for Modulator – PART C WARNING!- WARNING!-...
  • Page 45: Main Burner Removal / Burner System Removal / Installation

    All manuals and user guides at all-guides.com MCVST42 / MCVP42 Main Burner Removal If Glass Tray or Log Grates are installed, refer to MCVST42GT or MCVST42LG Installation / Removal page in this manual. To remove burner, Lift Pilot Shield off of Pilot. Remove four [4] screws from burner.
  • Page 46: Ipi Electronic Ignition System

    All manuals and user guides at all-guides.com IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that Cover provides you with the option of having either a Standing- Pilot, or an intermittent igniting system. This alternating Backup mode is controlled by the CPI/IPI Switch (Continuous Pilot Battery...
  • Page 47: Remote Control Operation

    All manuals and user guides at all-guides.com -Remote Control Operation- The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart thermostatic control of the appliance. Transmitter Remote Receiver Transmitter Room Thermostat ( Transmitter Operation) The Transmitter is powered by 3 AAA type batteries.
  • Page 48: Ipi Electronic Ignition Parts List - Standard System

    All manuals and user guides at all-guides.com IPI Electronic Ignition Parts List – Standard System ITEM NO. PART NO. DESCRIPTION 1006-P002si Valve IPI Hi/Lo NG 1006-P003si Valve IPI Hi/Lo LP *1002-P047si Pilot Assembly-LP -24” Wire *1002-P033si Pilot Assembly-NG -24” Wire 1002-P017si Spark Electrode (with wire) *1002-P119si...
  • Page 49: Configuration 1: Basic Manual Hi / Lo And Manual Off

    All manuals and user guides at all-guides.com Configuration #1: Basic Manual HI/LO and Manual ON/OFF Capabilities...
  • Page 50: Configuration #2: Remote On/Off And Manual Hi/Lo

    All manuals and user guides at all-guides.com Configuration #2: remote ON/OFF and Manual HI/LO Optional: For units with remote HI/LO capabilities a modulating servo is required to be installed on the valve. The connectors to this servo must be connected to the Remote Harness as shown in the figure below.
  • Page 51: Operating The Receiver Without Batteries For Gt / Egt / Gtm / Egtm Remote Controls

    All manuals and user guides at all-guides.com Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls -Wiring Harness P/N 1002-P906si required for both IPI & Millivolt systems. -Millivolt Systems will also require Power Adapter P/N 1002-P850si. The Remote Receiver &...
  • Page 52: Configuration 3: Remote On/Off, Variable Hi/Lo, And Fan

    All manuals and user guides at all-guides.com Configuration #3: Remote ON/OFF, Variable HI/LO, Lights and Fan NOTE: FAN IS NOT AVAILABLE ON 42MCVP UNITS.
  • Page 53: Electronic Ignition Lighting Instructions

    All manuals and user guides at all-guides.com Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed. FOR YOUR SAFETY READ BEFORE LIGHTING: A.
  • Page 54: Vent Termination

    The gas fireplace is approved to be vented either through the side wall or vertically through the roof. F - Clearance under veranda, porch, deck or balcony 12 inches 1 This appliance is approved with Kingsman flex vent system. (30cm) minimum. 4 US 5 ONLY VENTING COMPONENTS SPECIFICALLY APPROVED G - Clearance from a perpendicular inside wall or outer corner to AND LABELED FOR THIS FIREPLACE MAY BE USED.
  • Page 55: General Vent Installation

    General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex (Z-Flex) Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with 5 x 8 M&G-Duravent Direct Vent system (Model DV-GS Series), BDM Pro Form Direct Vent, Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.
  • Page 56: Venting Routes And Components

    All manuals and user guides at all-guides.com Venting Routes And Components Venting Routes and Components Since it is very important that the vent system maintain its How to Use the Horizontal Vent Table balance between the combustion air intake and the flue gas 1.
  • Page 57: Z58Ht Horizontal Installations- Wall Thimble Sizing / Termination Sizing

    All manuals and user guides at all-guides.com Z58HT Horizontal Installations- Wall Thimble Sizing / Termination Sizing- NOTE: If you are installing 5/8 Termination in an existing wall, measure diameter of both Wall Thimble and Termination. Wall Thimble mount plate comes in two sizes: Termination Plate comes in two sizes: 13-5/16”...
  • Page 58 All manuals and user guides at all-guides.com New Wall Thimble Old Wall Thimble Old Termination Old Termination 13-3/4" Wall Thimble 15-3/4" Wall Thimble Termination Termination 13-5/16" 13-5/16" 1-3/16" 3/16" Old Wall Thimble New Termination New Wall Thimble 15-3/4" New Termination Wall Thimble Wall Thimble 13-3/4"...
  • Page 59: Venting Straight Up Through Roof

    All manuals and user guides at all-guides.com Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed. It is designed to keep insulation materials away from the chimney. When installing the Attic Insulation Shield where the chimney passes from a living space to an attic space, install the shield from below and nail in place using 1"...
  • Page 60 All manuals and user guides at all-guides.com -Restrictor- Remove for Runs Under 15 Feet Clearances in horizontal venting. Z58VT 43ft Straight-through roof support configuration; b) Flex bend configuration; c) Termination mounting...
  • Page 61: Approved For Power Vent Pvh58

    All manuals and user guides at all-guides.com Approved for Power Vent PVH58 The PVH58 Horizontal Power Vent is approved for the following models only: MDV31, MDV39, MQRB3632, ZDV3622, MQZDV3622, ZDVRB3622, HBZDV3624, HBZDV3628, HBZDV3632, MQHBZDV3636, HBZDV4224, HBZDV4228, HBZDV4232, MQHBZDV4236, HBZDV4740, MQHBZDV4736, MQRB4436, MQRB5143, MQRB6961, ZRB46, ZCV39, ZCV42, MCVP42, MCVST42, MQZDV3927*, MQZDV4634* *NOTE: For MQZDV3927 and MQZDV4634, Power Vent Control Module (PVCM) must be placed outside of Fireplace.
  • Page 62: Pvh58 Parts List

    All manuals and user guides at all-guides.com PVH58 Parts List PVH58 HORIZONTAL POWER VENT TERMINATION: Listed for Canada and USA NUMBER DESCRIPTION MCVP42 & MCVST42 VENTING AND VENTING ADAPTERS -For fireplaces to be converted to hard pipe (M&G-Duravent-DirectVent Pro, etc.) at the fireplace: Z58DFA M&G-Duravent Fireplace Adapter -For Power Vent installations where flex pipe will be used up to the Power Vent unit:...
  • Page 63: Mcvp42 Parts List

    All manuals and user guides at all-guides.com MCVP42 Parts List Door Glass Fireplace Part Numbers 42HB-310 Tempered Glass-for Decorative MCVP42N (Millivolt) Fireplace Decorative rated, Units NG, Tempered Glass, Safety Screens 42HB-311 Ceramic Glass-for Heater Rated MCVP42NH (Millivolt) Fireplace Heater rated, NG, Units Ceramic Glass, Safety Screens MCVP42NE...
  • Page 64 FP15GC Stainless Steel Gas Connector GTRC Remote Control Millivolt - Thermostat Remote Control Millivolt – GTMRCN Thermostat/Modulating - NG KINGSMAN FIREPLACE VENTING Remote Control Millivolt – GTMRCP Thermostat/Modulating - LP Z58DFA M&G-Duravent Adapter (5 x 8) Remote Control Millivolt –...
  • Page 65: Limited Lifetime Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.

Table of Contents