Sensors List - Haier 1U12BS3ERA Service Manual

Wall mounted type dc inverter super match
Hide thumbs Also See for 1U12BS3ERA:
Table of Contents

Advertisement

TECHNICAL SPECIFICATIONS-OTHERS
Refrigerant type
Refrigerant charge
Refrigerant
Maximum allowable distance
circuit
between indoor an outdoor
Maximum allowable level difference
Refrigerant control
Piping connections
(external diameter)
Heat insulation type
Max. piping Length
Max. vertical Difference
Chargeless
Amount of Additional Charge of Refrigerant
Intemational Protection degree
Note: the data are based on the conditions shown in the table below
cooling
Indoor: 27 DB/19 WB
Outdoor: 35 DB/24 WB

3 Sensors list

type
Ambient sensor
Suction sensor
Defrosting sensor
Descharging sensor
liquid
gas
drain
heating
Indoor:20 DB
Outdoor: 7 DB/6 WB
Description
Its used for detecting temperature of outdoor side
Its used for detecting suction pipe temperature of compressor to
adjust gas flowing
Its used for controlling outdoor defrosting at heating mode
Its used for compressor in case of over-heat
KG
m
m
Capillary
mm
mm
mm
Both liquid and Gas pipes
m
m
m
g/m
IP 24
Piping length
5m
8
Specification
R410a
1.2
15
10
6.35
9.52
16
15
10
10
20
Conversation formulae
Kcal/h= KW×860
Btu/h= KW×3414
cfm=m³/min×35.3
Qty
1
1
1
1
Domestic air conditioner