Haier 1U12BS3ERA Service Manual page 19

Wall mounted type dc inverter super match
Hide thumbs Also See for 1U12BS3ERA:
Table of Contents

Advertisement

Cooling/dehumidification mode:
Serial No.
1
2
3
4
5
Remarks: the above are not only the maximum frequency limitations of the complete appliance
which are affected by the environment, but also the maximum ability limitation of the system. When the
starting ability is not the maximum, its maximum frequency limitation is calculated by the following
equations:
The frequency limitation which is affected by the temperature and under the condition of actual
ability the actual running system ability*the maximum frequency which is limited by the temperature
and under the condition of maximum ability/the maximum designing ability of the system
T=
Ti*Pi / Pi ( Ti=|Tst_i the setting temperature - Tnh_i the indoor environment
temperature|; Pi i the ability of the indoor unit)
Cooling/dehumidification mode:
The percentage of the
rated frequency P
Heating mode
The percentage of the
rated frequency P
The indoor setting
airflow speed
The percentage of the
rated frequency Ki
K= (Ki*Pi)/ Pi
The calculation of the actual output frequency:
when there is no healthy airflow: F= F-ED-*(rated frequency) P K
When the healthy airflow has been set: F =F-ED-* P K airflow speed
Notes:
When cooling, it is needed to satisfy
F-MIN-d(compressor's Min_hz)< F<F-MAX-d(compressor's Max_hz)
When heating, it is needed to satisfy
F-MIN-r (compressor's Min_hz)< F<F-MAX-r (compressor's Max_hz)
Temperature scope
Wh_c<28
Wh_c<32
Wh_c<40
Wh_c<48
Wh_c 48
T
<1
50%
T
<1
50%
Breeze
Low
Medium
60
75%
17
Frequency limitation
Max_hz1
Max_hz2
Max_hz3
Max_hz4
Max_hz5
1
2
80%
120%
150%
1
2
70%
120%
150%
High
Strong
85%
100%
120%
Functions and control
46HZ
72HZ
80HZ
65HZ
46HZ
3
>=4
160%
3
>=4
170%
Healthy
Quiet
airflow
60%
60%
K healthy airflow
Domestic air conditioner

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Super match 1u12bs3era