Directed Electronics Viper 5902 Installation Manual page 15

Responder hd models
Table of Contents

Advertisement

1.
On: the OEM Alarm Disarm wire will pulse as programmed when the Aux/Trunk output is activated
2.
Off: the OEM Alarm Disarm wire will not pulse when the Aux/Trunk output is activated
7. OEM Alarm Disarm Output (H2/1 wire)
1.
With Unlock: the OEM Alarm Disarm wire will pulse as programmed at the same time as the unlock
(Blue) wire
2.
Before Unlock: the OEM Alarm Disarm wire will pulse as programmed before the unlock wire
3.
Remote start only: the OEM Alarm Disarm wire will pulse as programmed during remote start only
8. OEM Alarm Disarm Pulses (H2/1 wire)
1.
1: the OEM Alarm Disarm wire will pulse once per operation
2.
2: the OEM Alarm Disarm wire will pulse twice per operation
9. Aux 1 Output Type (H2/6 wire)
1.
Validity: when the Aux command is received the wire will turn on and remain on until the command
ceases
2.
Latch: when the Aux command is received the wire will turn on and remain on until the command is
received again
3.
Latch/reset/Ignition: when the Aux command is received the wire will turn on and remain on until the
command is received again or the ignition is turned on/off
4.
Timed: when the Aux command is received the wire will turn on for the programmed time duration
(default 30sec)
5.
Off: the output will not activate for a remote control command, use this option when the Aux com-
mand controls an external device such as a garage door module
6.
2nd unlock: the wire will operate as 2nd unlock and will not activate for remote control commands
10. Aux 1 Linking
1.
No Linking: the Aux output will not activate for a remote control command
2.
Link to Arm: the Aux output will activate for the Arm command
3.
Link to Disarm: the Aux output will activate for the Disarm command
4.
Link to Arm/Disarm: the Aux output will activate for the Arm & Disarm commands
5.
Link to Remote Start: the Aux output will activate for any Remote Start activation
11. Aux 2 Output Type
Refer to Aux 1 Output Type descriptions
12. Aux 2 Linking
Refer to Aux 1 Linking descriptions
13. Aux 3 Output Type
Refer to Aux 1 Output Type descriptions
14. Aux 3 Linking
Options 1-4: Refer to Aux 1 Linking descriptions
Option 5: SmartKey Control (Link to Remote Start Off): The Aux output will pulse once following
Remote Start shut down for vehicles with push button engine stop operations. During runtime, if any
door is opened remote start will shut down immediately and pulse the output.
15. Aux 4 Output Type
Refer to Aux 1 Output Type descriptions
16. Aux 4 Linking
Refer to Aux 1 Linking descriptions
17. Aux/Trunk Output Type
Refer to Aux 1 Output Type descriptions
© 2009 Directed Electronics. All rights reserved.
15