4. Siren Duration
1.
30sec: the siren output for full trigger activations and Panic mode is 30 seconds
2.
60sec: the siren output for full trigger activations and Panic mode is 60 seconds
5. Ign-controlled Locks
1.
No Ign-locking: the door lock/unlock outputs will not activate when ignition is turned on/off
2.
Lock & Unlock: the door lock & unlock output will activate when ignition is turned on & off
3.
Lock Only: the door lock output will activate when ignition is turned on
4.
Unlock Only: the door unlock output will activate when ignition is turned off
6. Door Lock Pulses
1.
Single: the door lock & unlock outputs will pulse once
2.
Double Unlock only: the unlock output only will pulse twice
3.
Double Lock Only: the lock output only will pulse twice
4.
Double Lock & Unlock: the lock & unlock outputs will pulse twice
7. Door Lock Output Duration
1.
0.8sec.: the door lock output pulses will be 800mS in duration
2.
3.5sec.: the door lock pulses will be 3.5 seconds in duration
3.
0.4 sec.: the door lock pulses will be 400mS in duration
8. Ignition Controlled 2nd Unlock
1.
After first unlock: for Ign-controlled unlocking, the 2nd unlock will activate 800mS after the first (driver
door) unlock
2.
With first unlock: for Ign-controlled unlocking, the 2nd unlock will activate at the same time as the first
(driver door) unlock
9. Comfort Closure
1.
No comfort Closure: Comfort Closure is defeated when arming
2.
Comfort Closure 1: the door lock pulse (or 2nd pulse for double pulses) will remain on for 20 sec-
onds.
3.
Comfort Closure 2: 800mS following the end of the door lock pulse (or 2nd pulse for double pulses);
the door lock output will turn on again for 20 seconds.
10. Horn Function
1.
Full Alarm Only: the horn output will pulse only during full trigger events.
2.
Siren Function 20/30/40/50ms: The horn output will emulate the siren output with selectable output
timing to compensate for OEM horn inefficiency.
11. Hood Switch Type
1.
Normally Open: for vehicles with a hood switch that rests at ground when the hood is OPEN
2.
Normally Closed: for vehicles with a hood switch that rests at ground when the hood is CLOSED
12. Sensor Full Trigger
1.
Single: full trigger activation of only one sensor is required to fully trigger the alarm
2.
Double: full trigger activation of two sensors within a ten second period is required to fully trigger
the alarm.
13. Door Switch Type
1.
Normally Open: for vehicles with door switches that rest at ground when the door is OPEN
2.
Normally Closed: for vehicles with door switches that rest at ground when the door is CLOSED
14. Trunk Switch Type
1.
Normally Open: for vehicles with a trunk switch that rests at ground when the trunk is OPEN
2.
Normally Closed: for vehicles with a trunk switch that rests at ground when the trunk is CLOSED
15. Remote Button Unlock (Ign off)
1.
On: a message telling the 2-way remote control to unlock the keypad is sent each time the vehicle
ignition is turned off
2.
Off: no message is sent
© 2009 Directed Electronics. All rights reserved.