Menu 2 - Convenience - Directed Electronics Viper 4104 Installation Manual

Keyless entry and remote start
Table of Contents

Advertisement

Menu 2 - Convenience

Menu
Feature
Item
1
One-time Bypass
2
Override Pulse Count
3
Door Open Error chirp*
4
Ign-controlled Dome light
5
OEM Alarm Disarm w/Aux/
trunk
6
OEM Alarm Disarm Output
7
OEM Alarm Disarm Pulses
8
Aux 1 Output type
9
Aux 1 Linking
10
Aux 2 Output type
11
Aux 2 Linking
12
Aux 3 Output type
13
Aux 3 Linking
14
Aux 4 Output Type
15
Aux 4 Linking
16
Aux/Trunk Output type
* The Green H2/6 or the Violet H2/12 wire must be connected to enable this feature.
1. One-time Bypass
1. Off: One-Time Bypass is not available
2. On: the One-Time Bypass feature will defeat Passive Locking once and, if Locked by remote control,
will defeat Comfort Closure and Aux outputs linked to Locking
2. Override Pulse Count
1-5: sets the number of presses (1-5) on the Control Button required to override the alarm system
3. Door Open Error chirp
1. On: if the door trigger is active when locking, the horn will emit a honk and a message will be sent
to the 2way remote control as an alert
2. Off: an active door trigger when locking will not create an alert output
4. Ign-controlled Dome light
1. On: the dome light output will activate when the ignition is turned off
2. Off: the dome light output will not activate when the ignition is turned off
5. OEM Alarm Disarm w/Aux/Trunk (H2/4 wire)
1. On: the OEM Alarm Disarm wire will pulse as programmed when the Aux/Trunk output is activated
2. Off: the OEM Alarm Disarm wire will not pulse when the Aux/Trunk output is activated
6. OEM Alarm Disarm Output (H2/4 wire)
1. With Unlock: the OEM Alarm Disarm wire will pulse as programmed at the same time as the unlock
(Blue) wire
© 2011 Directed Electronics. All rights reserved.
Opt. 1
Opt. 2
No Bypass
Bypass
2
1
Off
On
On
Off
On
Off
With Unlock
Before Unlock
2
1
Latch
Validity
No Linking
Link to Lock
Validity
Latch
No Linking
Link to Lock
Validity
Latch
Link to Lock
No Linking
Validity
Latch
No linking
Link to Lock
Validity
Off
Opt. 3
Opt.4
3
4
Remote Start
Only
Latch/reset/
Timed
ign
Link to Unlock
Link to Lock/
Unlock
Latch reset/ign
Timed
Link to Unlock
Link to Lock/
Unlock
Latch reset/ign
Timed
Link to Unlock
Link to Lock/
Unlock
Latch reset/ign
Timed
Link to Unlock
Link to Lock/
Unlock
2nd unlock
Opt. 5+
5
Off (5)/2nd
Unlock (6)
Link to Remote
Start only
Off (5)/2nd
unlock (6)
Link to Remote
Start only
Off (5)/2nd
unlock (6)
Smart Key
Control (Link to
Remote Start
Off)*
Off (5)/2nd
Unlock (6)
Link to Remote
Start Only
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clifford 410.4xPython 414

Table of Contents