Crestron TPMC-CH-IMW Operation Manual

Crestron TPMC-CH-IMW Operation Manual

Cat balanced av interface wall plate

Advertisement

Quick Links

Crestron TPMC-CH-IMW
CAT5 Balanced AV Interface Wall Plate
Operations Guide

Advertisement

Table of Contents
loading

Summary of Contents for Crestron TPMC-CH-IMW

  • Page 1 Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate Operations Guide...
  • Page 2 This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2006 Crestron Electronics, Inc.
  • Page 3: Table Of Contents

    Crestron TPMC-CH-IMW Contents CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW Introduction...1 Features & Functions...1 Specifications...2 Physical Description ...4 Industry Compliance...10 Setup...11 Network Wiring ...11 CAT5 Wiring ...11 Hardware Hookup...11 Problem Solving...15 Troubleshooting...15 Check Network Wiring...15 Reference Documents...17 Further Inquiries ...17 Future Updates...17...
  • Page 5: Cat5 Balanced Av Interface Wall Plate: Tpmc-Ch-Imw

    NET connector • Supports composite, S-video, and component video • Connects to conventional audio and coaxial video sources The TPMC-CH-IMW is not compatible with QuickMedia™ touchpanels or touchpanels with a 10-pin RJ-45 NET/VIDEO connector. Operations Guide – DOC. 6448 CAT5 Balanced AV Interface Wall Plate CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW •...
  • Page 6: Specifications

    CAT5 Balanced AV Interface Wall Plate Specifications Specifications for the TPMC-CH-IMW are listed in the following table. TPMC-CH-IMW Specifications SPECIFICATION Front Panel AUDIO Output Impedance Maximum Output Level Input Impedance VIDEO Output Impedance Rear Panel VIDEO Input Impedance Input Level...
  • Page 7 Includes black metal front panel Decora Decora faceplate (provided by others). 4.11 in (10.44 cm) 3.50 in (8.89 cm) 1.66 in (4.22 cm) 7.5 oz (0.21 kg) CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW • 3 DETAILS ® inserts; requires...
  • Page 8: Physical Description

    CAT5 Balanced AV Interface Wall Plate Physical Description This section provides information on the connections and indicators available on your TPMC-CH-IMW. Physical View of the TPMC-CH-IMW, Front 4 • CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW Crestron TPMC-CH-IMW Operations Guide – DOC. 6448...
  • Page 9 Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate Physical View of the TPMC-CH-IMW, Rear CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW • 5 Operations Guide – DOC. 6448...
  • Page 10 CAT5 Balanced AV Interface Wall Plate TPMC-CH-IMW Overall Dimensions (Clockwise from top – Front, Side, Rear) 6 • CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW Crestron TPMC-CH-IMW 3.50 in (8.89 cm) 4.11 in (10.44 cm) Operations Guide – DOC. 6448 1.66 in...
  • Page 11 5-pin terminal block connector for twisted pair wiring of balanced or unbalanced audio signals to the touchpanel. Pin 1: Left + Pin 2: Left - Pin 3: Ground Pin 4: Right + Pin 5: Right - CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW • 7...
  • Page 12 AUDIO OUT PIN 1 PWR LED AUDIO PIN 1 (continued on following page) 8 • CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW Crestron TPMC-CH-IMW DESCRIPTION 4-pin terminal block connector for data and power. Interface connector for the Cresnet connector is provided.
  • Page 13 Y- (Luminance) (S-video) Y- (Y/Pb/Pr) Pin 3: C+ (Chrominance) (S-video) Pb+ (Y/Pb/Pr) Pin 4: Pr+ (Y/Pb/Pr) Pin 5: Pr- (Y/Pb/Pr) Pin 6: C- (Chrominance) (S-video) Pb- (Y/Pb/Pr) Pin 7: N/C Pin 8: N/C CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW • 9...
  • Page 14: Industry Compliance

    Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. 10 • CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW Operations Guide – DOC. 6448 Crestron TPMC-CH-IMW...
  • Page 15: Setup

    Contact with thermal insulating materials should be avoided on all sides of the unit. Operations Guide – DOC. 6448 CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW • 11 CAT5 Balanced AV Interface Wall Plate...
  • Page 16 Refer to the following diagrams to connect balanced or unbalanced video signals. Balanced Video Connection JUMPERS REMOVED 12 • CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW Operations Guide – DOC. 6448 Pro-e (VT Pro-e) project. Unbalanced Video Connection Crestron TPMC-CH-IMW CRESNET:...
  • Page 17 For the proper orientation of the two insert plates with respect to the installed TPMC-CH-IMW, refer to the following diagram. Operations Guide – DOC. 6448 CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW • 13 CAT5 Balanced AV Interface Wall Plate...
  • Page 18 The triamese cable has labels indicating the port to connect. Connecting to the Touchpanel AUDIO: CONNECT TO AUDIO PORT TOUCHPANEL 14 • CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW Operations Guide – DOC. 6448 Crestron TPMC-CH-IMW NET: CONNECT TO NET PORT ON TOUCHPANEL...
  • Page 19: Problem Solving

    Certified Wire, may be used. Failure to do so may incur additional charges if support is required to identify performance deficiencies as a result of using improper wire. Operations Guide – DOC. 6448 CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW • 15 CAT5 Balanced AV Interface Wall Plate POSSIBLE...
  • Page 20 Cresnet connector and tighten the retaining screw. Repeat the procedure for the other three conductors. 16 • CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW Operations Guide – DOC. 6448 L = Length of run (or chain) in feet. Where: R = 6 Ohms (Crestron Certified Wire: 18 AWG (0.75 MM...
  • Page 21: Reference Documents

    Check the Crestron website periodically for manual update availability and its relevance. Updates are identified as an “Addendum” in the Download column. Operations Guide – DOC. 6448 CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW • 17 CAT5 Balanced AV Interface Wall Plate...
  • Page 22: Return And Warranty Policies

    (property or economic damages inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a third party or made by the purchaser for a third party.
  • Page 23 Crestron TPMC-CH-IMW CAT5 Balanced AV Interface Wall Plate This page intentionally left blank. Operations Guide – DOC. 6448 CAT5 Balanced AV Interface Wall Plate: TPMC-CH-IMW • 19...
  • Page 24 Crestron Electronics, Inc. Operations Guide – DOC. 6448 15 Volvo Drive Rockleigh, NJ 07647 (2014256) Tel: 888.CRESTRON 03.06 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.

Table of Contents