Components
Oven Sensor
Door switch
Broil element
Bake element
Test procedures
1. Refer to page 3-11 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1000)
NOTE: Oven sensor is so sensitive to temperature
Do test after cooling down sufficiently
1. Refer to page 3-5 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1000)
1. Refer to page 3-6 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
1. Refer to page 3-7 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
4-3
Results
Normal: Approximately
1.09 kΩ ± 10%
If not replace
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Door open
Door closed
Continuity
Infinite
Normal: Approximately
14 Ω ± 10%
If not replace
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
Normal: Approximately
17 Ω ± 10%
If not replace
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.