Caution! Before connecting up the appliance to new
pipework or to pipework that has not been used for
some time, run off a reasonable amount of water to flush
out any debris that may have collected
Caution! Do not use the hose from your previous
appliance to connect to water supply.
The inlet hose is screwed to the back of the appliance.
35°
The other end of the inlet hose which connects to the
appliance can be turned as showed in the picture.
Do not place the inlet hose downwards. Angle the hose
to the left or right depending on the position of your
water tap. Set the hose correctly by loosening the ring
nut. After positioning the inlet hose, be sure to tighten
the ring nut again to prevent leaks.
Caution! The inlet hose must not be lengthened. If it
is too short and you do not wish to move the tap,
you will have to purchase a new, longer hose specially
designed for this type of use.
Warning! Installation should comply with local
water authority and building regulations'
requirements.
The appliance must be connected to a cold water supply.
A minimum water pressure of 0.05 MPa (0.5 bar) is
required for safe operation of the appliance.
If you cannot make the cold water connection direct from
the rising mains, you may be able to operate the appliance
from your cold water storage system.
Connect the hose to a tap
with a 3/4" thread. Always
use the hose supplied with
the appliance.
45°
There should be a minimum vertical distance of 5.02 m
(16.5 ft) between the appliance's inlet and the bottom of
the water storage tank.
Water drainage
This appliance is designed to be permanently plumbed in-
to your home's drainage system using one of the follow-
ing methods.
1. Into a drainage standpipe.
Firstly form a hook in the end of the drain hose using
the "U" piece" supplied.
"U" piece supplied
Place the drain hose into your standpipe, which should
have an internal diameter of approximately 38 mm thus
ensuring there is an air break between the drain hose
and standpipe.
When discharging into a standpipe ensure that the top
of the standpipe is no more than 90 cm (35.4'') and no
less than 60 cm (23.6'') above floor level.
The drain hose may be extended to a maximum of 4
metres. An additional drain hose and joining piece is
available from your local Service Force Centre. The
joining piece must have an internal diameter of 18 mm.
38 mm (1.5")
standpipe
diamater
30 cm (12")
25