Bryant ERVBBLHA A07619 Product Data page 6

Energy recovery ventilators

Advertisement

ACCESSORIES
ITEM
Bryant OneTouch Control
Bryant Basic Wall Control
Bryant Latent Wall Control
60--- Minute Timer Kit
Bryant 20--- Minute Push Button
Airflow Measuring Kit
Hood (2 required)
ACCESSORY DESCRIPTION, SUGGESTED AND REQUIRED USE
Bryant OneTouch Control
Control option choice. Used with all ERVs as a main wall control.
Bryant Basic Wall Control
Control option choice. Can be used with all ERVs.
Bryant Latent Wall Control
Control option choice. Can be used with all ERVs.
60- -Minute Timer Kit
Used with all ERVs, time is adjustable between 10 and 60 minutes.
Bryant 20- -Minute Push Button
Used with all ERVs when 20 minute manual operation is required
Airflow Measuring Kit
Start up Balancing Kit, includes Magnehelic Gauge
Hood (2 required)
Used with all ERVs. Exterior intake and exhaust hoods.
Control Description
OneTouch
Latent
Control features
OneTouch Control:
Allows control of ventilator with the touch of a button. This
control will operate as a main wall control. The OneTouch will
operate the unit in Intermittent Mode (20 minutes per hour),
continuous low speed, continuous high speed, and off.
Latent Control:
Low Exchange Mode—If the relative humidity inside the building
is lower than selected, air exchange would occur with the outside at
high speed. If the relative humidity inside the building is higher
than selected, air exchange would occur with the outside at low
speed. This ensures continuous air exchange for constant air
quality.
Model
ERVBBLHA
* All defrost times are in the standard mode (as shipped)
{ Time between defrost when within specified temperature range
E2007 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
KVBCN0101BLT
KVBCN0101BBS
KVACN0101BLC
KVATM010160M
KVATM010120B
KVBAC0101KIT
KVAAC0101HOD
Fan Speed Control
Yes
Yes
25_F
(---5_C)
DEFROST*
EXCHANGE{
10 Minutes
60 Minutes
ACCESSORY PART NO.
Humidistat Control
Continuous Mode
No
Yes
Intermittent Mode—If the relative humidity inside the building is
higher than selected, no air exchange would occur and the system
would turn off. If the relative humidity inside the building is lower
than selected, air exchange would occur with outside at high speed.
this mode is ideal for maintaining the proper humidity level when
the continuous mode cannot.
Automatic Defrost Cycle Features
All models offer a non- -electric defrost cycle feature which
prevents frost and ice buildup within the heat recovery core. When
the outside air temperature falls below 23_F (- -5_C) it is
electronically sensed and the dampers close the outside air ports.
This allows warm indoor air to recirculate within the heat recovery
core. The frequency of this cycle increases as the outside air
temperature decreases.
4_F TO ---17_F
(---15.6_C TO ---27.3_C)
DEFROST*
EXCHANGE{
10 Minutes
30 Minutes
Printed in U.S.A.
6
ERVBBLHA SIZE USED WITH
All
All
All
All
All
All
All
Intermittent Mode
Yes
Yes
BELOW ---18_F
(---27.8_C)
DEFROST*
10 Minutes
Catalog No: PDSERVLHA ---01
Edition Date: 07/07
Yes
Yes
EXCHANGE{
20 Minutes
Replaces: NEW