Armcor REM900 Installation And Operation Manual

Rotary heat wheel unit

Advertisement

Quick Links

Installation and
Operation Manual
REM – Rotary Heat Wheel Unit
REM900 – REM8000
Manufactured
Manufactured
by Armcor
by Armcor

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the REM900 and is the answer not in the manual?

Questions and answers

Summary of Contents for Armcor REM900

  • Page 1 Installation and Operation Manual REM – Rotary Heat Wheel Unit REM900 – REM8000 Manufactured Manufactured by Armcor by Armcor...
  • Page 2: Table Of Contents

    Contents Equipment Application Safety Location of Equipment Minimum Access Requirements for Maintenance Noise Levels Fresh Air Inlet and Exhaust Air Outlet Drainage Installation Instructions Unpacking and Inspection Unit Handling Lifting with a Crane Lifting with a Forklift Equipment Connections Ductwork Filters Electrical Requirements Mains Power Supply and Fusing...
  • Page 3: Equipment Application

    Every proposed installation must be subject to an engineered design by a mechanical services consultant. Armcor Air Solutions is not responsible for performance of equipment in applications for which the equipment was not designed or specified. REM – Rotary Heat Wheel Unit Installation and Operation Manual 2021...
  • Page 4: Safety

    Check with Armcor Air Solutions for any information required on this equipment. DANGER Electrical shock can cause personal injury or death.
  • Page 5: Location Of Equipment

    Location of Equipment It is important that the selected location for the equipment is suitable and can adequately accommodate the unit physical size, the unit weight and has safe and suitable access for correct operation and future maintenance requirements. Minimum Access Requirements Fresh Air Inlet and Exhaust for Maintenance Air Outlet...
  • Page 6: Installation Instructions

    If damage is evident it should be noted on the freight Wear safety goggles, work gloves, work boots and docket and contact is to be made with the Armcor protective clothing. Air Solutions sales office. A claim should be lodged •...
  • Page 7: Equipment Connections

    • The power requirement and voltage are detailed on for the specified airflow without excessive pressure the equipment technical specifications (available at armcor.com.au) and are on the identification/serial levels. The unit should be situated as close as possible to the point of use to prevent unnecessary no.
  • Page 8: Standard Equipment Layout

    Standard Equipment Layout Fresh Air Supply Air Exhaust Air Return Air REM – Rotary Heat Wheel Unit Installation and Operation Manual 2021...
  • Page 9: General Maintenance

    • Armcor Air Solutions are pleased to provide expert • Cleanable Filters. advice on special service maintenance requirements If filters are cleanable, they should be cleaned once a for particular installations.
  • Page 10: Warranty

    Warranty The Armcor Air Solutions Warranty Policy should be read in conjunction with the Terms and Conditions of Sale. These are available on our website armcor.com.au What The Warranty Policy Covers • Any warranty work performed by Armcor Air Solutions outside of Melbourne metro area will...
  • Page 11: Pre-Start Checklist

    Pre-start Checklist Unit Installation and Connections Check that equipment is fully installed in accordance with the installation instructions Visually check that air flows will not be obstructed Electrical Visually check all field wiring Tighten all electrical connections including all factory wiring connections Ensure supply cable is correct size Check the required supply voltage is available on all phases Check overload settings are correct (if applicable)
  • Page 12: Commissioning Checklist

    Commissioning Checklist General Air Filters: Overall Size and Number Drain Pipe Traps and Vents fitted to Indoor Unit as per Installation Instructions Y / N Drain is Clearing Water Properly Y / N Check Vibration of Unit OK / EXCESSIVE Belt Tensioning Adjusted Y / N Rotary Heat Wheel is Operating...
  • Page 13 Notes ........................................................................................................................................................................................................................................................REM – Rotary Heat Wheel Unit Installation and Operation Manual 2021...
  • Page 14 Notes ........................................................................................................................................................................................................................................................REM – Rotary Heat Wheel Unit Installation and Operation Manual 2021...
  • Page 15 Notes ........................................................................................................................................................................................................................................................REM – Rotary Heat Wheel Unit Installation and Operation Manual 2021...
  • Page 16 E: sales@armcor.com.au P: (03) 8301 9200 109–111 Northcorp Blvd Broadmeadows Vic 3047 © 2021 Armcor Air Solutions reserves the right to alter products and specifications without notice and does not accept responsibility for possible errors and omissions in published documentation.

This manual is also suitable for:

Rem8000

Table of Contents