CF(M)-3K-12 SUPERCOMBI USER'S GUIDE

4.5 Float Charge

The user can enable or disable the Floating Charge function by varying setting
of the dial switch (See Fig 13).
1. When the Floating Charge function is enabled, the SuperCombi will still
charge the battery at very small current to compensate the self-discharging
current;
2. When the Floating Charge function is disabled, the SuperCombi will stop
charging untill the battery voltage is only 1 volt higher than the cut off Voltage.

5. Operation Guide

5.1 Invert

When disconnected with the Grid, the SuperCombi has two working statuses
according to different Auto Invert settings:
1. When Auto Invert function is enabled, the SuperCombi will output AC power
to Short Break connection unless the Rocker Switch stays on the center
position. The status indicator on the remote control panel will turn green (see
Appendices), and AC power will be drawn from the battery;
2. When Auto Invert function is disable, the SuperCombi will enter into Standby
mode. The indicator will turn Red (see Appendices).
Note: Please find more information about the Energy Save mode in 5.2

5.2 Energy Save Mode

To reduce the power consumption when the SuperCombi work when there is
no load, the user can choose Energy Save Mode by putting the Rocker Switch
to the lower position. Under the Energy Save Mode, if the AC load of the
system is less than 30W in 10 minutes, the SuperCombi will enter into Standby
21