Summary of Contents for Spinner BN 754066C0001

  • Page 1 SPINNER I Product Manual Coaxial two-way RF switch (DPDT) RF interface N Female BN 754066C0001 BN 754066C0002 products.spinner-group.com...
  • Page 2: Table Of Contents

    Improper use ............................. 3 Qualifications of personnel ........................ 3 Safety signs and symbols ........................4 Signal words for hazard seriousness ....................4 Grouped safety instructions for SPINNER broadcast products............5 Product identification ......................... 7 Delivery content ..........................7 Function ............................. 7 Impulse solenoid drive ........................
  • Page 3: Safety

    1.1 About this product documentation The Spinner group makes every effort to keep the safety standard of our products up to date to be able to offer our customers the highest possible degree of safety. Our products are designed and tested in accordance with the relevant safety standards.
  • Page 4: Safety Signs And Symbols

    SPINNER I Product Manual 1.5 Safety signs and symbols Safety signs are used on warning labels, stickers, in the product documentation and on the packaging of the product. Warning! Warning! Warning! PE terminal Earth Warning! General hazard Danger of Hot surface...
  • Page 5: Grouped Safety Instructions For Spinner Broadcast Products

    (allergens) such as nickel cannot be generally excluded. If you develop an allergic reaction (such as a skin rash, frequent sneezing, red eyes or respiratory difficulties) when using a SPINNER product, consult a physician immediately to determine the cause and to prevent health problems or stress.
  • Page 6 "Qualifications of personnel"). Observe the safety instructions and in particular chapter 1. "Safety" of this product manual. Failure to comply could result in death or serious injury.  Do not modify the product and use only spare parts tested and approved by SPINNER. Failure to comply could result in death or serious injury.
  • Page 7: Product Identification

    SPINNER I Product Manual 2. Product identification The SPINNER RF switches BN 754066C0001 and BN 754066C0002 have a type label containing the following information for product identification: 01 BN 754066C0001 (SPINNER part number) 01 BN 754066C0002 (SPINNER part number) Ser. No. XXXXXX...
  • Page 8: Manual Override

    SPINNER I Product Manual 4.4 Manual override The switch position can be selected by the user manually with the manual override. The manual override is used exclusively for manual switching of the RF switch in the de-energized and load-free state. The RF switch is mechanically interlocked in the end position.
  • Page 9: Installation

    Before you start, ensure to read and understand the safety instructions and in particular chapter 1. "Safety" of this product manual. Only electrically skilled persons may install SPINNER RF switches in accordance with the national safety and accident prevention regulations. Failure to comply could result in death or serious injury.
  • Page 10: Mechanical Installation

    SPINNER I Product Manual WARNING Lightning hazard Lightning may cause electric shock, burns and serious injury. Use suitable overvoltage protection to ensure that no overvoltage (such as that caused by a bolt of lightning) can reach the product. Use a copper lead (min 6 mm²) to connect the marked earthing terminal to the main...
  • Page 11: Electrical Installation

    1. "Safety" of this product manual. Only electrically skilled persons may operate SPINNER RF switches in accordance with the national safety and accident prevention regulations. Failure to comply could result in death or serious...
  • Page 12: Cleaning

    SPINNER I Product Manual CAUTION Risk of burns, cuts and needle stick injuries Touching the manual override during electrical switching may cause injuries. Do not touch the manual override during electrical switching. CAUTION Hot surface The RF switch heats up during normal operation. Touching it may cause burns.
  • Page 13: Repairs

    Before you start, ensure to read and understand the safety instructions and in particular chapter 1. "Safety" of this product manual. Only electrically skilled persons may demount SPINNER RF switches in accordance with the national safety and accident prevention regulations. Failure to comply could result in death or serious injury.
  • Page 14: Disposal

    Sharp edges may cause cuts and needle stick injuries. Use safety gloves and handle carefully. NOTICE The supplied packaging is reusable and required for transportation. If not available, contact SPINNER before starting demounting. Follow the procedure described in chapter 7 in reverse order. 15. Disposal WARNING Risk of poisoning from decomposed PTFE RF overload can lead to formation of decomposed PTFE.
  • Page 15: Environmentally Friendly Usage Period

    SPINNER I Product Manual 16. Environmentally friendly usage period 产品在正常使用条件下, 环保使用期限才在此标识有效期内. The environmental protection use period is valid if the product is used as intended. 有毒有害物质或元素 Toxic or hazardous substances and elements 部件名称 铅 汞 镉 六价铬 多溴联f 多溴二f醚 Component name...
  • Page 16: Contacts

    For support and information contact the local SPINNER sales office. The current contact addresses are available on the website http://www.spinner-group.com. To ensure best possible support always refer to the SPINNER part number and serial number of the product. SPINNER GmbH • Headquarters Erzgiessereistr.