Download Print this page

Yaesu HX290 Alignment Manual page 3

Advertisement

Before Alignment
Install the HX290 Service Flag Controller Program to your computer.
Set up the test equipment as shown below, and set the DC Power Supply voltage to
8.0 V.
Execute the HX290 Service Flag Controller Program.
Select the COM port number which is connected to the HX290 Alignment Jig.
Press and hold in the [PRESET] key while turning the transceiver on to enter the
Alignment Mode.
Select "Alignment" ON of HX290 Service Flag Controller Program.
Click the left mouse button on the [SET] button of the HX290 Service Flag
Controller Program.
Main Reference Frequency Adjustment
Setup the test equipment as shown below.
Set the channel to CH16.
Use the [H/L] key to set the transceiver to "LOW" power.
With the PTT switch pressed, adjust VR1002 so that the Frequency Counter
reading is 156.800 MHz ±100 Hz.
Transmit Power Adjustment
Setup the test equipment as shown below.
Set the channel to CH16.
Use the [H/L] key to set the transceiver to "HI" power.
With the PTT switch pressed, adjust VR1003 so that RF output power is 5 W ±0.1
W.
Release the PTT switch, then set the transceiver to "LOW" power by the [H/L] key.
With the PTT switch pressed, adjust VR1001 so that RF output power is 0.8 W ±0.1
W.
Release the PTT switch.
TX Deviation Adjustment
Setup the test equipment as shown below.
Set the AF Signal Generator output to 200 mV rms at 1 kHz.
Set the channel to CH16.
With the PTT switch pressed, adjust VR1004 so that the maximum deviation is 4.2
kHz ±0.1 kHz.
3
Vertex Standard Co., Ltd.
FCC ID: K6630453X20
ID: 511B-30453X20
Alignmenmt

Advertisement

loading