FLS FlowX3 F9.20 Instruction Manual

Battery powered flow monitor

Advertisement

Quick Links

Table of Contents

1. Introduction............................................................................ 3
1.1.
Safety Instructions......................................................................... 3
1.2.
Unpacking..................................................................................... 3
2. Description............................................................................. 4
2.1.
Design.......................................................................................... 4
2.2.
Technical Features........................................................................ 4
2.3.
Connection to FlowX3 Sensors....................................................... 4
3. Specifications......................................................................... 5
3.1.
Technical Data.............................................................................. 5
3.2.
Dimensions.................................................................................. 6
4. Installation............................................................................. 7
4.1.
Panel Installation.......................................................................... 7
4.2.
Wall Installation............................................................................ 8
4.3.
Compact Installation..................................................................... 8
4.4.
Wiring.......................................................................................... 9
5. Operational Overview.............................................................. 11
5.1.
Keypad Functions......................................................................... 11
5.2.
General Operation Flowchart.......................................................... 11
6. View Level.............................................................................. 13
7. Menu Directory Level............................................................... 13
7.1.
Free access (no password required)................................................ 14
7.2.
Password protected access............................................................ 14
1
F9.20 Battery Powered Flow Monitor
EN 05-03

Advertisement

Table of Contents
loading

Summary of Contents for FLS FlowX3 F9.20

  • Page 1: Table Of Contents

    F9.20 Battery Powered Flow Monitor INSTRUCTION MANUAL EN 05-03 Table of Contents 1. Introduction…………………………………………………………………. 3 1.1. Safety Instructions………………………………………………………………. 3 1.2. Unpacking…………………………………………………………………………. 3 2. Description………………………………………………………………….. 4 2.1. Design……………………………………………………………………………... 4 2.2. Technical Features……………………………………………………………… 4 2.3. Connection to FlowX3 Sensors………………………………………………. 4 3. Specifications………………………………………………………………. 5 3.1.
  • Page 2 8. Menu and Edit Level………………………………………………………. 15 8.1. Calibration Menu…………………………………………………………………… 15 8.1.1. Unit………………………………………………………………………………. 15 8.1.2. K-Factor…………………………………………………………………………. 16 8.1.3. Inftot Backup……………………………………………………………………. 16 8.4. Options Menu……………………………………………………………………….. 17 8.4.2. Filter……………………………………………………………………………… 17 8.4.3. Flow Decimal Point…………………………………………………………….. 18 8.4.4. Total Decimal Point…………………………………………………………….. 18 8.4.7. Menu PWD……………………………………………………………………… 19 8.4.8.
  • Page 3: F9.20 Battery Powered Flow Monitor

    1. Introduction 1.1. Safety Instructions General Statements Do not install and service the instrument without following the Instruction Manual. Unit installation and wiring connections should only be performed by qualified staff. Do not modify product construction. Installation and Commissioning Statements To clean the unit, use only chemical compatible products.
  • Page 4: Description

    2. Description 2.1. Design The FLS FlowX3 F9.20 Battery Powered Flow Monitor is equipped with two long life lithium batteries and it integrates the power supply for the sensor. It is designed to show on the LCD display flow rate and totalized flow volume with no external power supply required.
  • Page 5: Specifications

    3. Specifications 3.1. Technical Data General Associated flow sensor: • FLS FlowX3 Coil effect with frequency output • FLS FlowX3 Reed effect Materials: • Case: PC • Panel gasket: Neoprene • Wall & Field gasket: EPDM • Keypad: 5-button silicone rubber Display: •...
  • Page 6: Dimensions

    3.2. Dimensions Compact Mount Panel Mount Wall Mount F9.20 Battery Powered Flow Monitor...
  • Page 7: Installation

    4. Installation The battery powered flow monitor is available just in one packaging for compact field version, panel or wall installation. The compact field version is mounted on top of the sensor using the compact mounting kit (F9.KC1), the panel version is installed using the panel mounting kit (F9.KP1), while the wall mounting version is fixed with the wall mounting kit (F9.KW1).The mounting kits can be ordered directly connected to the monitor or separately and then simply installed on it.
  • Page 8: Wall Installation

    4.2. Wall Installation The wall mounting version consists of the monitor and the wall mounting kit. The F9.KW1 kit includes the plastic adapter with gasket for IP65 watertight wall installation and the fixing screws. 1. Fix the wall mounting kit to a solid wall using the included screws.
  • Page 9: Wiring

    4.4. Wiring ll wiring connections to F9.20 are made via removable terminals. Flow sensor terminals are orange, all other terminals are green. eneral recommendation Terminals accept 26 to 12 AWG (0.08 to 2.5 mm trip around 10 mm (0.4”) of insulation from the wire tips and tin bare ends to avoid fraying.
  • Page 10 Sensor Wiring Diagram 3.00.C IP68 or F3.01.C (compact version) F3.00.C IP65 flow sensor connection flow sensor connection LFXX.R flow sensor connection • Maximum cable length is 16 m (52.8 ft). F9.20 Battery Powered Flow Monitor...
  • Page 11: Operational Overview

    5. Operational Overview he FlowX3 F9.20 battery powered flow monitor, like all members of X3 Line, features a digital display and a five-button keypad for system set-up, calibration and operation. This section contains a description of the keypad functions and the general operation flowchart of the instrument.
  • Page 12 F9.20 Battery Powered Flow Monitor...
  • Page 13: View Level

    6. View Level • During normal operation, the flow monitor is in View Level displaying all measured values. • If the flow monitor is in a different level and no activity occurs for more than 3 minutes, it will return to View Level. •...
  • Page 14: Free Access (No Password Required)

    7.1. Free access (no password required) 7.2. Password protected acc ess F9.20 Battery Powered Flow Monitor...
  • Page 15: Menu And Edit Level

    Menu and Edit Levels 8.1. Calibration Menu The F9.20 basic settings are made in this menu: To set flow rate and totalizer Engineering Units To set K-Factor 8.1.1. Unit Set the engineering units for the instant flow rate and the total flow rate. All the options available are displayed on the LCD.
  • Page 16: K-Factor

    8.1.2. K-Factor Set the K-Factor to tell t he monitor and transmitter how to convert the input frequency om the flow sensor into a flow rate. The K-factor is unique to the sensor model and to the pipe size and material. Refer to section 10.
  • Page 17: Options Menu

    .2. Options Menu To select the averaging level of LCD, output and relay response To set the flow rate decimal point position To set the totalizer decimal point position To set ON or OFF password protection to enter Menu Levels To set ON or OFF password protection to reset totalizer...
  • Page 18: Flow Decimal Point

    8.2.2. Flow Decimal Point et the decimal point position to get the best solution pplication. Select llowing optio .XXXX ; XX.XXX ; XX.XX ; XXXX.X ; XXXX. 8.2.3. Total Decimal Point Set the decimal point position to get the best resolution application.
  • Page 19: Menu Pwd

    8.2.4. Menu PWD ON the Menu PWD to tect access to Menu ectory Level and next els. NOTE: the standard password is and it cannot be modified. .2.5. Restot PWD t ON the Restot PWD to tect resettable alizer from undesired et operations.
  • Page 20: K-Factor Calculate

    8.2.6. K-Factor Calculate Option used to perform automatic calculation of K-Factor by measuring the volume filled into a tank. This to get the highest accuracy possible. Press ENTER to start calculation. Switch on a pump or open a valve. F9.2 0 starts counting pulses from the s ensor.
  • Page 21: Troubleshooting

    9. Troubleshooting The instrument correctly installed is maintenance-free. The case and the front panel can cleaned with soft cloth and an appropriate cleaning agent. 9.1. Display messages Display Causes Solutions • Flow rate is in OVERFLOW: it • Change flow rate exceeds maximum...
  • Page 22: K-Factor Tables

    10. K-Factor Tables 0.1 K-Factor values for Te e-Fittings ISO PN10 Dimensions K-Factors D(mm) DN(mm) PVDF Metal 235.45 212.17 225.06 142.46 135.32 139.38 157.06 91.53 89.36 94.66 92.84 51.57 48.94 51.37 42.89 42.10 43.07 10.2 K-Factor values f or ISO plastic saddles on PN 10 plastic pipes Dimensions K-Factors...
  • Page 23: Ordering Data

    Flow X3 F9 .20.P1 (P anel Mount version) Part No. Descrip tion F9.20.P1 Panel Mount Battery Powered Flow Monitor FlowX3 F9.20.WX (Wall Mount version) rt No. escrip tion F9.20.W1 Wall Mo Battery Pow ered F low Moni Flow X3 F 9.00.XX (Compact Field Mount version...
  • Page 24 Mounting Kits Part No. Description Plastic adapter with gasket, compact cap, locking F9.KC1 Compact mounting Kit ring and 4 fixing screws F9.KP1 Panel mounting Kit Mounting bracket with gasket F9.KW1 Wall mounting Kit Plastic adapter with gasket and fixing screws F9.KW1 F9.KP1 F9.KC1...
  • Page 25 Spare Parts em Part No. Name Description F9.SP3 Cover PC front cover, no LED PG13.5 Cable Gland for Compact or Wall F9.SP4.1 PG 1 mounting Kit PG11 Cable Gland for Compact or Wall mounting PG 11 Replacement battery 3.6 Volt Lithium thionyl chloride battery F9.SP6 F.I.P.

Table of Contents