Page 1
Compact Flow Monitor F9.XX assembling into Plastic Saddles DN > 200 and Metal Strap-on Saddles INSTRUCTION MANUAL EN 09-05 1. Dismount the F9.XX Flow Monitor 1.1. Remove the front cover 1.2. Unscrew four screws and remove the monitor 1.3. Disconnect the sensor from compact mounting kit...
Page 2
3. Screw-in the insert (3) The insert must be completely screwed-in; if it doesn’t, please double-check the position of the sensor pins. 4. Position the adapter (4) on top of insert (3) and fix it using the nut (5) 5. Fix the compact mounting kit (6) tightening the locking ring (7) 6.