3/4" Plywood

1. Prepare the Site

NOTICE: Select 3/4" plywood with a maximum height of 9" (22.9
cm). This will provide proper structural integrity for the vanity
installation.
Measure and mark 33" (83.8 cm) up from the floor. This will be
the height from the top of the 3/4" plywood to the floor.
Notch the studs so the front of the 3/4" plywood will be flush
with the edge of the studs.
NOTICE: The backing should be at least 30" (76.2 cm) long and be
aligned with the vanity.
Secure the 3/4" plywood to the studs with framing nails.
Install the water supply and drain lines according to the
roughing-in information provided with your lavatory. The water
supply nipples must extend at least 3" (7.6 cm) beyond the
finished wall material.
NOTE: Plumbing fittings will be exposed and visible once the vanity
installation is complete. Plated plumbing fittings are recommended.
Complete the finished wall. Ensure the finished wall is straight
and plumb, and the floor is flat and perpendicular to the finished
wall.
NOTICE: Before installing molding to the finished wall, check to
ensure that it will not interfere with the vanity.
1082745-2-A
9" (22.9 cm)
33"
(83.8 cm)
30" (76.2 cm) Min