UNIT SIZE-SERIES
Operating Weight (Lb)
ELECTRICAL
Unit Volts-Hertz-Phase
Operating Voltage Range
Unit Ampacity for Wire Sizing
Min Wire Size (60 C/75 C Copper) (AWG)*
Maximum Length (60 C/75 C) (Ft)**
Max. Branch Circuit Fuse Size (Amps)‡
Compressor Rated Load Amps
Locked Rotor Amps
Fan Motor HP and RPM
Full Load Amps
COMPRESSOR AND REFRIGERANT
Compressor
Refrigerant—Type and Amount (Lb)†
OUTDOOR COIL AND FAN
Coil Face Area (Sq Ft)
Rated Airflow (CFM)
OPTIONAL EQUIPMENT
Support Feet—4 In. (4)
Snow Stand—18 In.
Time-Delay Relay
Interface Control‡‡‡
Service Alarm
Outdoor Thermostat
Secondary Outdoor Thermostat
Cycle Protector
Crankcase Heater
Start Assist—PTC
Start Capacitor and Relay
Sound Hood
Bi-flow TXV Kits (Hard Shutoff)
Bi-flow TXV Kits (RPB)
Low-Pressure Switch
High-Pressure Switch
Evaporator Freeze Thermostat
Isolation Relay
Liquid Solenoid Valve (LSV)
Filter Drier—Bi-flow
Low-Ambient Controller
MotorMaster® Control
Ball Bearing Fan Motor
Thermostat, Auto Changeover,
Non-Programmable, F/ C,
2-Stage Heat, 1-Stage Cool
Thermostat, Auto Changeover,
7-Day Programmable, F/ C,
2-Stage Heat, 1-Stage Cool
Thermostat, Manual Changeover,
Non-Programmable, F,
2-Stage Heat, 1-Stage Cool
Thermostat, Auto Changeover,
Non-Programmable, F/ C,
Dual Fuel Thermostat. Must be used with
Outdoor Sensor (TSTATBBSEN01)
Outdoor Sensor
* If wire is applied at ambient greater than 30 C (86 F), consult Table 310-16 of the NEC (ANSI/NFPA 70). If other than uncoated (non-plated), 60 or 75 C
(140 or 167 F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the
NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC
(ANSI/NFPA 70) Article 336-30.
† The factory refrigerant charge is for 15 ft of interconnecting tubing. For tubing lengths other than 15 ft, see Long-Line Application Guideline for additional
refrigerant requirements.
‡ Time-delay fuse or HACR breaker.
** Length shown is as measured 1 way along the wire path between the unit and the service panel for voltage drop not to exceed 2%.
†† For indicator light function, thermostat specified must be used and wired according to efficiency service alarm Installation Instructions.
‡‡ Used with low-ambient controller.
*** Fan motor with ball bearings required.
††† High-pressure switch must be added if not supplied with the system.
‡‡‡ Outdoor thermostat required.
N/A—Not Applicable
SPECIFICATIONS Continued
048-A
265
34.0
8/10
91/56
50
26.5
129.0
1/8 and 820
1.0
R-22 and 11.88
18.18
2900
KHASS0206MPK
KHATX1301HSO
—5—
208/230-60-1
187—253
Scroll
R-22 and 14.88
KSASF0101AAA
KHASS0306MPK
KAATD0101TDR
KHAIC0101AAA
KHASA0101AAA††
KHAOT0301FST
KHAOT0201SEC
Standard
Standard
KAACS0201PTC
KSAHS1601AAA
Standard
KHATX1401HSO
N/A
Standard
Standard
KAAFT0101AAA‡‡
KHAIR0101AAA‡‡
KHALS0101LLS
P504-8163S (RCD)
P251-0083 (RCD)
32LT660004***
HC38GE230 (RCD)
TSTATBHNHP01-A
TSTATBHPHP01-A
HH07AT214
TSTATBHPDF01-A†††
TSTATBBSEN01
060-A
327
45.0
6/8
116/66
60
34.9
169.0
1/5 and 820
1.4
24.89
3600