INDOOR
AIR
–3
Capacity
Total
(MBtuh)
Pwr
EDB
CFM
Total
Int*
Kw† Total
1100
16.0
14.7
2.43
1200
16.2
14.9
2.46
65
1300
16.4
15.1
2.48
1100
15.7
14.5
2.52
70
1200
15.9
14.6
2.55
1300
16.1
14.8
2.57
1100
15.4
14.1
2.62
75
1200
15.6
14.3
2.64
1300
15.7
14.5
2.67
Indoor
Section
Size
FC4BN(F,B)
042
FC4BNF
033
036
F(A,B)4ANF
036
F(A,B)4AN(F,B)
042
FG3AAA
036
FK4BNF
001
002
003
004
FK4CNF
001
002
003
CD5A/CD5BW
036
CC5A/CD5A/CD5BA
036
042
043
CC5A/CD5A/CD5BW
042
043
CD3(A,B)A
036
042
CE3AA
036
042
CF5AA
036
CJ5A/CK5A/CK5BA
036
042
CJ5A/CK5A/CK5BN
042
CJ5A/CK5A/CK5BW
036
CK3BA
036
042
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
042
CC5A/CD5A/CD5BW
042
CD3(A,B)A
042
CC5A/CD5A/CD5BC
048
CE3AA
042
CJ5A/CK5A/CK5BA
036
CK3BA
036
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
042
CC5A/CD5A/CD5BW
042
CD3(A,B)A
042
CC5A/CD5A/CD5BC
048
CE3AA
042
CJ5A/CK5A/CK5BA
042
See notes on page 34.
HEAT PUMP HEATING PERFORMANCE Continued
OUTDOOR COIL ENTERING AIR TEMPERATURES F
7
17
Capacity
Total
Capacity
(MBtuh)
Pwr
(MBtuh)
Int*
Kw† Total
Int*
697C036-B Outdoor Section With FC4BN(F,B)042 Indoor Section
19.3
17.7
2.53
22.8
20.8
19.4
17.9
2.55
23.0
21.0
19.7
18.1
2.58
23.2
21.1
19.1
17.5
2.64
22.6
20.6
19.2
17.7
2.66
22.8
20.8
19.4
17.8
2.68
23.0
20.9
18.9
17.3
2.74
22.4
20.4
19.0
17.5
2.76
22.6
20.6
19.2
17.6
2.78
22.7
20.7
Multipliers for Determining the Performance With Other Indoor Section
Heating
Capacity
Power
1.00
1.00
1.00
1.00
1.00
1.03
1.00
1.03
1.00
1.00
1.00
1.03
1.00
1.00
1.00
0.97
0.99
0.94
1.00
0.92
0.98
0.99
0.99
0.97
0.98
0.94
1.00
1.01
1.00
1.01
1.00
1.01
1.00
1.01
1.00
1.02
1.00
1.01
1.00
1.01
1.00
1.01
1.00
1.02
1.00
0.99
1.00
1.01
1.00
1.01
1.00
0.99
1.00
0.99
1.00
1.01
1.00
1.01
1.00
0.99
0.98
0.98
0.98
0.98
0.98
0.98
0.98
1.00
0.99
0.97
0.99
0.97
0.99
0.97
0.98
0.96
0.98
0.96
0.98
0.96
0.97
0.98
0.98
0.95
1.00
0.96
27
Total
Capacity
Total
Capacity
Pwr
(MBtuh)
Pwr
(MBtuh)
Kw† Total
Int*
Kw† Total
2.64
26.7
23.7
2.74
31.2
2.65
26.9
23.9
2.75
31.4
2.66
27.1
24.1
2.76
31.6
2.75
26.5
23.5
2.87
30.9
2.76
26.7
23.7
2.87
31.1
2.78
26.9
23.9
2.88
31.3
2.87
26.2
23.3
2.99
30.6
2.88
26.4
23.5
3.00
30.8
2.89
26.6
23.6
3.01
31.0
Indoor
Section
CJ5A/CK5A/CK5BW
CK3BA
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CC5A/CD5A/CD5BW
CD3(A,B)A
CC5A/CD5A/CD5BC
CE3AA
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BW
CK3BA
COILS
333(B,J)AV060120 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CC5A/CD5A/CD5BW
CD3(A,B)A
CC5A/CD5A/CD5BC
CE3AA
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BW
CK3BA
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CD3(A,B)A
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BW
CK3BA
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CD3(A,B)A
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BN
CK3BA
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CD3(A,B)A
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BW
CK3BA
—30—
37
47
Total
Capacity
Total
Pwr
(MBtuh)
Pwr
Int*
Kw† Total
Int*
Kw† Total
28.4
2.87
36.1
36.1
3.03
28.6
2.87
36.4
36.4
3.03
28.7
2.88
36.6
36.6
3.03
28.1
3.00
35.7
35.7
3.17
28.3
3.00
36.0
36.0
3.16
28.5
3.01
36.2
36.2
3.16
27.8
3.14
35.4
35.4
3.31
28.0
3.14
35.6
35.6
3.30
28.2
3.14
35.9
35.9
3.30
s
Heating
Size
Capacity
036
0.98
036
0.98
042
1.00
042
0.98
042
0.98
042
0.98
048
0.97
042
0.98
042
0.99
036
0.98
036
0.98
042
0.99
042
0.98
042
0.98
042
0.98
048
0.97
042
0.987
042
0.99
036
0.98
036
0.98
042
0.99
042
1.00
042
1.00
042
1.00
036
1.00
036
1.00
042
1.00
042
1.00
042
1.00
036
1.00
042
1.00
036
1.00
042
1.00
042
0.99
042
0.99
042
1.00
036
1.00
036
1.00
042
1.00
—
—
57
Capacity
Total
(MBtuh)
Pwr
Int*
Kw†
41.8
41.8
3.23
42.1
42.1
3.22
42.4
42.4
3.22
41.3
41.3
3.37
41.6
41.6
3.36
41.9
41.9
3.35
40.9
40.9
3.52
41.2
41.2
3.50
41.5
41.5
3.50
Power
0.95
0.95
0.96
0.95
0.95
0.95
0.97
0.94
0.94
0.94
0.94
0.94
0.96
0.96
0.96
0.98
0.95
0.94
0.95
0.95
0.94
0.98
0.98
0.97
0.98
0.98
0.97
0.98
0.98
0.98
0.97
0.98
0.97
0.97
0.97
0.97
0.98
0.98
0.97
—